Faults
141
Code Group Description Possible
cause Remedies
tions
A16 Information
Maximum
pump
speed exceeded
PTO speed too
high
Reduce PTO
speed
A17
Fault
Fault in nozzle
control system
Nozzle faulty
Wiring faulty
Check nozzle
status in the in-
formation menu
Check the wiring
18.4
B – Cable breaks
These vary according to the version of the implement.
Code Output Description
Possible
cause
Remedies
B01
SA1
Y2 arm 4, left
Cable connection
defective
Visual
inspection
Replace cable if ne-
cessary
B02
SA2
Y4 valve, arm 3,
left
Cable connection
defective
Visual
inspection
Replace cable if ne-
cessary
B03
SA3
Y6 valve, arm 2,
left
Cable connection
defective
Visual
inspection
Replace cable if ne-
cessary
B04
SA4
Y8 valve, arm 1,
left
Cable connection
defective
Visual
inspection
Replace cable if ne-
cessary
B05
SA5
Y10 valve, arm 1,
right
Cable connection
defective
Visual
inspection
Replace cable if ne-
cessary
B06
SA6
Y12 valve, arm 2,
right
Cable connection
defective
Visual
inspection
Replace cable if ne-
cessary
B07
PA1
Y14 valve, arm 3,
right
Cable connection
defective
Visual
inspection
Replace cable if ne-
cessary
B08
PA2
Y16 valve, arm 4,
right
Cable connection
defective
Visual
inspection
Replace cable if ne-
cessary
B09
PA3
Swing lock valves
Y18/Y19
Cable connection
defective
Visual
inspection
Replace cable if ne-
cessary
B10 PA4 Slope
compensa-
tion valves
Y20/21
Cable connection
defective
Visual
inspection
Replace cable if ne-
cessary