Page 48/95
21January2021/Version 0
LEM International SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES Switzerland
www.lem.com
5.5.2. Accuracy
Parameter
Symbol
Unit
DCBM 400 DCBM 600
Comment
Accuracy class
B
B
Meter type
Direct connected meter
Current specification (Uninterrupted duty)
Reference current
I
ref
A
80
120
According to EN 50470-3
and EN 50470-1
Minimum current
I
min
A
4
6
Transitional current
I
tr
A
8
12
Maximum current
I
max
A
400
600
Starting current
I
start
mA
320
480
Voltage specification
Range of operation
U
n
V DC
150 - 1000
Maximum limit range of operation
U
max
V DC
1100
Minimum limit range of operation
U
min
V DC
130
Energy measurement bandwidth
DC
Cable loss compensation
mΩ
0 - 14
By steps of 2 mΩ, imported
energy only. Selectable
by charger controller or fix
value
Test Output LED
Imp/
kWh
1000
(see product designation)
Counting direction
Bidirectional
5.5.3. Insulation
Note
:
1)
Reinforced insulation is provided by the Sensor Unit (DCBM-SU40xx/DCBM-SU60xx).
The DCBM Meter Unit operates in SELV only
Parameter
Symbol
Unit
Value
Comment
Insulation type
Reinforced insulation
1)
According to IEC 60664-1
Rated insulation RMS voltage
U
Nm
V
1000
Overvoltage category
OV II
Impulse withstand voltage 1.2/50 μs
U
Ni
kV
8
RMS voltage for AC insulation test, 50/60 Hz, 1 min
U
d
V
4400
Pollution degree
PD2
Maximum altitude m 2000
m
2000
Voltage sense terminals - rated insulation between
poles
kV DC
1
Basic insulation, PD2
Case material
V0
According to UL 94