9
How to program calling numbers
You can program up to 8 or 9 calling numbers.
If you w ant to alarm more than the first three calling numbers you
have to adapt calling number sequence.
☞
P.9
Calling number 9 is used for periodical test call according EN81-28.
Digit
#
. as part to the calling number results i n a 5 seconds dialling
delay. This may be necessary in combi nation with a private exchange,
when a pause is required after taki ng an external line. Program calling
number as following: Office #. + Phone number
If you require Hotline-mode (= pri vate exchange dials telephone
number after E XICALL® EN70 seizes line) you program calling number
1 with
#
. onl y.
If the private exchange needs flash-pulse to dial internal numbers you
have to program calling number as following:
2
.
#
. + internal
number.
Calling number 1 cannot be deleted and is the only calling number to
be dialled i n case of a suppl y pow er loss.
Digit
*
. as part of the calling number will result into a Point-ID-
connection.
☞
P.21
How to program periodical test number
According to EN81-28 EXICALL® EN70 has to call his service facility at least
every 72 hours => periodical test call. Therefore you have to program
calling number 9.
If the periodical test call is activated EXICALL® EN70 calls this number
in the programmed interval.
☞
P.25
The periodi cal test can be activated / de-acti vated i.e. duri ng a remote
access (dialling in) usi ng DTMF commands.
☞
P.16
How to check calling numbers
Check calling numbers i.e. calling number 1 by entering:
PROG
✓
☞
S.8
*
.
*
.
9
.
ANNOUNCEMENT
*
.
Calling number according
to specification sheet
Wait for 5
sec.
BEEP
PROG
✓
☞
P.8
*
.
*
.
1
.
ANNOUNCEMENT
Wait for
20 sec.
BEEP
PROG
✓
☞
P.8
*
.
*
.
1
.
ANNOUNCEMENT
*
.
Calling number according
to specification sheet
Wait for 5
sec.
BEEP
PROG
✓
☞
P.8
*
.
*
.
2
.
ANNOUNCEMENT
*
.
Calling number according
to specification sheet
Wait for 5
sec.
BEEP
PROG
✓
☞
P.8
*
.
*
.
3
.
ANNOUNCEMENT
*
.
Calling number according
to specification sheet
Wait for 5
sec.
BEEP
..
..
..
..
..
..
..
PROG
✓
☞
P.8
*
.
*
.
8
.
ANNOUNCEMENT
*
.
Calling number according
to specification sheet
Wait for 5
sec.
BEEP