8
Programming
Preparation
1.
EXICALL® EN70 will be programmed locally over the mi crophone usi ng
a DTMF-dialler (Touch-Tone-Dialler). Therefore, ambient noise can
affect the programming.
2.
Connect supply voltage
☞
P.12
3.
Place Dialler over the microphone.
Enable programmi ng
4.
Press call button briefly. The mode LE D Mode changes from flashing to
permanently green.
5.
Press key
*
. on the dialler. The mode LED changes to off.
6.
A. You hear one beep followed by the announcement "Programming
disabl ed, PIN". Enter the PIN code (factory setting: 0000) followed by
key
#
. . You will hear two beep sounds and the programming is
enabl ed. Wait for any announcements and conti nue with step 4. .
6.
B. You hear one beep only. EXICALL® EN70 is now in programming
mode. Start programmi ng sequence by entering first key within 5
seconds, otherwise programming mode is exited (go back to step 4, if
you want to proceed with programmi ng).
Information on programming
Programming will be PIN-code protected automatically after first call
started from the EXICALL ® EN70 to ensure that EXICALL ® EN70 is
protected against unauthorized changes after the i nstallation.
The programming mode is left automatically w hen there will be no
DTMF received withi n 5 seconds (=timeout).
As long as the yellow LED is on, you are not able to do any
programming. Wait until the yellow LE D is off.
Programming remains stored even after pow er-loss.
PROG
✓