16
Other remote controls / Elevator al arm and Door phone mode
Do not delay more than two seconds between two digits.
Other remote controls / Door phone
Do not delay more than two seconds between two digits.
DTMF commands
*
.
*
.
0
.
Read-out/ Modify calling number sequence (1->-2->3)
*
.
*
.
1
.
Read-out / Modify calling number1
..
..
*
.
*
.
8
.
Read-out / Modify calling number 8
*
.
*
.
9
.
Read-out / Modify periodical test number
*
.
*
.
#
.
0
.
Deactivate periodi cal test to calling number 9
*
.
*
.
#
.
1
. <n>
Activate periodical test to calling number 9 (first time in 72 h or after <n>
hours)
*
.
*
.
#
.
2
.
Start communi cation test to calling number 9 in two mi nutes (once only)
*
.
*
.
#
.
#
.
Modif y individual message
DTMF commands
EXICALL® EN70
disconnets
*
.
2
.
Close contact K3 for 2 seconds
Yes
*
.
3
.
Close contact K3 for 4 seconds
Yes
*
.
4
.
Close contact K3 for 8 seconds
Yes
*
.
5
.
Contact K3 on 3s, off 1s, on 3s
Yes
*
.
6
.
Close contact K3 for 2 seconds
No
*
.
7
.
Close contact K3 for 4 seconds
No
*
.
8
.
Close contact K3 for 8 seconds
No
*
.
9
.
Close contact K3 until disconnection
No
*
.
0
.
Disconnect if S1 (door contact) is acti ve
If input S1 is active
*
.
1
.
EXICALL® EN70 disconnects
Yes