10
How to program calling number sequence
The factory default for calling number sequence is
1
.
2
.
3
. . EXICALL®
EN70 calls the numbers of the sequence consecuti vel y until the call is
acknowledged or the end of the sequence is reached.
You can adapt the sequence i n case you w ant to call a certai n number
repeatedly.
Examples:
Calling number sequence
fact ory setting
1
.
2
.
3
. : Call number 1, the n
number 2 followed by number 3.
Calling number sequence
1
.
1
.
3
.
3
.
2
.
2
.
2
.
2
. : Call number 1 tw o
times, followed by two attempts on number 2, followed by four attempts on
number 3.
Calling number sequence
2
.
3
.
1
. : First call to number 2, than number
three and number 1 in the end. In case of a pow er loss onl y calling number
1 can be dialled.
The calling number sequence can contai n up to 9 digits.
The calling number sequence may be altered usi ng day/ night-input
(S4). If so, enter calling number other sequence while input signal S4
is active. During operation the calling number sequence follows the
input signal on S4.
☞
P.21
If a calling number is not programmed or erased, this number will be
skipped when still programmed in calling number sequence.
In case of a power loss E XICALL® EN70 can alarm calling number 1
only. Please make sure that at least on calling number is availabl e in
any case at any time, i.e. calling number sequence= 231:
How to program indi vidual announcement / Select language
You can record an individual announcement to i dentify your EXICALL®
EN70. The optional input
<n>
allows altering the user language: Press
1
.
for German,
2
for French,
3
. for E nglish,
4
. for Italian.
The maximum recording time is 12 seconds
Depending on the sel ected profile this announcement will be pl ayed
once at the begi nni ng of each alarm connection, or repeated every <x>
seconds during the connection or even without any announcement (i.e.
as door phone)
☞
P.7
How to program the PIN-Code
The PIN code protects the EXICALL ® EN70 against unauthorized remot e
dial-up or programmi ng. It also can be used to identify the unit duri ng
phone connection (i.e. commission number of elevator)
The PIN code must be between four and seven digits.
The
fact ory setting
for the PIN code is
0000
. Program a different
code for security reasons.
Unit powered
In case of power loss
Calling number sequence
231
Calling numbe 1 only
2: 0#044…
1: 0#043…
3: 0#079…
-
1: 0#043…
-
PROG
✓
☞
S.8
#
.
PIN code accrodi ng to
specification sheet
#
.
Repeat PIN
code
#
.
BEEP
BEEP
PROG
✓
☞
P.8
*
.
*
.
#
.
ANNOUNCEMENT
<n>
*
.
Announcement
accordi ng to
specification sheet
#
.
BEEP
Wait for
5 sec.
PROG
✓
☞
S.8
*
.
*
.
0
.
ANNOUNCEMENT
*
.
Calling cumber sequence
accordign to spec. sheet
Wiat for 5
sec.
BEEP