53
Proceed as follows:
Select:
Select the desired setpoint for drive, temperature or air with the
Confirm (33) button.
Representation:
The selected area is indicated by a bar at the side
Setting:
Use the
Plus/Minus buttons (32)
to adjust the selected setpoint to match your
requirements.
You can regulate the setpoints of the three welding parameters individually, even during operation.
During operation, the selected range automatically switches back to the row
welding speed (35) after 5 sec-
onds.
The units for the welding speed and for the temperature can be adjusted.
Temperature:
°C
or
°F
Speed:
m
min
or
ft
min
• Hold down the
Drive On/Off (30)
and
Heating On/Off (31)
buttons and connect
the power cord to the power supply. The display now shows UNIT.
• Press the
Confirm (33)
button to confirm and use the
Plus/Minus (32)
buttons to
set the desired units.
• Press the
Confirm (33)
button to confirm and use the
Plus/Minus (32)
buttons to
select SAVE. Press the
Confirm (33)
button to confirm; the units are then saved.
The device then restarts automatically.
16.2 Setting the welding parameters
16.1 Setting the parameter units
16. Settings and functions of the UNIROOF 300 software
Содержание UNIROOF 300
Страница 28: ...28 Switching off Target and Actual Value Display see 10 4 Switching on ECO Mode see 10 5...
Страница 29: ...29 Switching off Data Recording see 10 6 Switching on Advanced Mode see 10 7...
Страница 37: ...37 10 7 Advanced mode settings Example Activate WLAN Press 4 times...
Страница 38: ...38 Switch on Info Mode Example Setting the time...