Obstacle
Wall
7.2 Operating readiness
Check nozzle setting
Installing the guide bar
• Check nozzle setting: Nozzle must have a distance of approx. 2-3 mm from the base material.
1. Loosen the locking screw of the
guide bar (18)
.
2. Fold up the guide bar 90° and retighten the
locking screw of the guide bar (18).
Make sure that the guide
bar is positioned perpendicular (90°) to the machine, otherwise the function of the
wall switch (16)
is not
guaranteed.
3. Push
the guide bar at the top (21)
into the
guide bar at the bottom (19)
and lock into place at the desired
height with the
clamping lever on the guide bar (20)
.
Depending on where the automatic welder is used, it can be helpful to completely disassemble the guide bar.
For example, if there is an
obstacle
(radiator or similar) on the
wall
.
2 - 3 mm