![Leister UNIFLOOR 500 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/leister/unifloor-500/unifloor-500_manual_1873915019.webp)
19
40
13
11
38
29
39
10
Nozzle positioning gauge
9. UNIFLOOR 500 settings
9.1 Adjust track
• Check the alignment of the
guide roller (10), welding nozzle (6)
and
wire pressure roller (11).
These three components must be in line.
• Lift the wire
pressure roller (11)
using the
lever of the wire pressure roller (13)
.
• Place the
nozzle positioning gauge
(included in the scope of delivery) on the floor and place the hot-air
welder on top of it as shown in the image below.
• Swivel the
hot-air blower (7)
manually to the lower stop.
• Check whether the
welding nozzle (6)
is parallel to the corresponding groove in the nozzle positioning gauge.
• If not, loosen the 4
hexagon socket screws (40)
using the supplied pin torx wrench (T15) and align the
nozzle so that it is parallel to the groove. To do this, you can swivel the
hot-air blower (7)
up and down as
desired. Then retighten the 4 screws.
• Loosen the
locking screw of the wire pressure roller (38)
with the supplied hexagon pin wrench (SW3).
• With the
lever of the wire pressure roller (13)
lower the
wire pressure roller (11)
and, if necessary, align
laterally so that the
guide roller (10), welding nozzle (6)
and the
wire pressure roller (11)
are centered in
the respective groove of the
nozzle positioning gauge
.
• Tighten the
locking screw of the wire pressure roller (3)
.
• Check the alignment of the
wire guide tube (29)
to the
wire pressure roller (11)
. The lower part of the
wire guide tube (29)
must be centered to the
wire pressure roller (11)
.
• If the orientation of the
wire guide tube (29)
is not correct, loosen the
locking screw of the wire guide tube
(39)
.
• Align the
wire guide tube (29)
and retighten the
locking screw of the wire guide tube (39)
.
Danger of burns
Do not touch the heating element tube, nozzle and linoleum flap when hot. The device should always
first be allowed to cool down.
Before setting up the UNIFLOOR 500, disconnect the
power cord (1)
from the device.