![Leister UNIFLOOR 500 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/leister/unifloor-500/unifloor-500_manual_1873915010.webp)
10
Actual and setpoint value of the welding speed
Actual and setpoint value of the air volume
Welding temperature too low, heat-up process.
Up arrow shows
that the desired
higher temperature
has not yet been reached.
The flashing number designates the currently achieved actual value (430);
the value below (450) shows the setpoint of the individual setting.
Welding temperature too high, cool-down process.
Down arrow
shows that the desired
lower temperature
has not yet been reached.
The flashing value designates the currently achieved actual value (470);
the value below (450) shows the setpoint of the individual setting.
6.4 Display symbols for the welding speed (35)
Heating
The LED on the
Heating “On/Off” button (31)
displays the respective condition of the heating.
LED status heating “On/Off” (31) Condition
LED off
Heating is switched off.
LED flashes green
Heating is switched on. Temperature is outside the tolerance range.
LED green
Heating is switched on. Temperature is within the tolerance range.
6.5 Display symbols for the welding temperature (36)
6.6 Display symbols for the air volume (37)
6.7 Status LED display
Heating and drive
If both LEDs of the
Heating “On/Off” button (31)
and the
Drive “On/Off” button (30)
flash simultaneously,
there is an error (see Chapter
Warning and Error Messages 11).
drive
LED status drive “On/Off” (30)
Condition
LED off
Drive is switched off
LED green
Drive is switched on
The LED on the
Drive “On/Off” button (30)
displays the condition of the drive.