46
iCONgrade, Operation
Gain
This is the scaling of hydraulic speeds for each of the sensors.
To enter
Gains
select the
Lower Left
or
Lower Right
buttons to open up the available
sensors. Select appropriate sensor and then the
or
key (depending on left or right
side) to enter the
Adjust
Menu.
The automatic hydraulic calibration will calculate the optimal gain values.
It is recommended not to change these values.
Elevation:
Press the Test button to adjust the value so that it corresponds to the below distances. For
example, during 2 seconds of movement, the blade should move 13 cm for GPS.
Second laser for cross slope:
This should be measured 1.5 meters from the centre of the blade. Press the Test button to
adjust the value so that it corresponds to the below distances. For example, during 2
seconds of movement, the blade should move 8 cm for a laser sensor controlling tilt.
Laser: 8 cm.
Sensor
Dozer
Grader
Laser/Sonics/Tri-Sonics/GPS
13 cm
13 cm
Tracker
7 cm
7 cm