32
iCONgrade, Operation
2.4.1
Installation and Set Up Tri-Sonic Sensor
Mounting the Tri-Sonic
Sensor
The Tri-Sonic can be installed quickly and easily with the simplest of tools.
Mount a support in a suitable location that is adjustable for height and lateral motion. This
will enable setting up of the Tri-Sonic over any reference. The support may differ according
to the machine and reference.
In case of large differences in temperature between the storage and working environments,
allow 30 minutes for the sensor to adapt to the working environment prior to operation.
The direction of move-
ment of the Tri-Sonic
sensor
While ground and curb scanning, the Tri-Sonic should move longitudinally for the averaging
of the scanned values.
For Stringline and Edge the Tri-Sonic should be placed at an angle of 90° to the reference
with the face plate orientated to back of the machine.
a) Working direction
b) stringline
a
b