18
iCONgrade, Operation
2.1.2
Mast orientation
Mast orientation
For Dozers and Graders without mast slope sensor, you must make sure that the mast is at
the “as measured” position (that is, the position the mast or masts were in during the mast
measure up).
On a Dozer this means that the mast should not be mechanically sloped. If for some reason
the mast is actually mechanically sloped, a new mast measure up must be done.
On a Grader the blade should be tipped back towards its end stop, if that was the original
measure position.