1.
Usage limits
Intended use
The LEIBINGER filling machine CANVASA II + II is designed for the automatic filling of bever-
ages in the temperature range from 0 to 20 °C, and for the sealing of cans.
Only beverage cans that are capable of withstanding the internal pressure generated by the filling
process may be used as filling containers.
The LEIBINGER filling machine CANVASA II + II must only be used for filling goods that have
been explicitly approved by LEIBINGER.
Misuse
The following points shall be regarded as misuse and must be avoided at all costs:
Any use other than that described by the manufacturer
Use of filling containers not approved by LEIBINGER
Use of incorrect or no can guide parts (adapter pieces)
Temperature range of the filling medium outside the permitted tolerance
Incorrect pressure settings for CO
2
, compressed air and the product
No or incorrect parameter adjustment after retrofitting
Use of unsuitable cleaning agents (danger of machine damage)
Insufficient ventilation of the machine and its immediate surroundings => risk of suffocation
Operating the machine using spare parts other than original Leibinger spare parts
Incorrect loading of the filling containers (e.g. inserting the can upside down)
Loading of the machine with damaged filling containers
Spatial limits
The required space is stated in the overview plan of the machine. See machine layout: "CAN-
VASA II + II.
The machine must be freely accessible from all sides.
A working area of approx. 1.5 m around the machine must be reserved for cleaning and mainte-
nance work.