8.
Connecting the machine
Media connections
The following connections can be found on the connection panel for the hose connections:
Fig. 4 Connection panel
Water connection:
The can spray and high-pressure injection are supplied via the water connection. Drinking water
quality is essential because the water also enters the product via the high-pressure injection.
CO
2
connection:
The CO2 connection supplies the pre-gassing, bubble breaker and bottom lid gassing. N
2
can
also be used here in principle. However, this can lead to increased O
2
uptake.
Rinser connection:
There is a separate connection for the rinser so that the rinsing medium can be freely selected.
Both water as well as inert gases (e.g. CO
2
, compressed air etc.) can be connected.
Compressed air connection:
All pneumatic movements are supplied via the compressed air connection.
Important information!
The connections on the connection panel are G3/8.
The operator is responsible for connecting all supply lines for the connection panel properly
and for checking them regularly.
Compressed air, CO
2
Attention! Risk of tripping