29
6 Appendix
6.4 Troubleshooting
Troubleshooting LEHNER
MiniVario®
Status: 01/2009
The following information should help you resolve minor problems yourself. You are welcome to call us as needed. We are glad to
help.
Problem
Cause
Resolution
The control panel crackles
Loose contact on the power supply
Check contacts and fuses
No display
+ and - were switched, fuse is defective
Check connections and fuses
Spreading disc does not reach set speed
Excess load, motor bearing not running smoothly
Check motor for ease of movement
Slide jams
Spreading material or dirt has got jammed in the slide
Check slide for foreign bodies and clean
On the display: Disc blocking
Spreading disc does not turn; switched off after 10 attempts
Check spreading disc
Possibly start spreader again
On the display: Agitator stationary
Agitator does not turn; switched off after 10 attempts
Check agitator
Material may be compacted
Possibly start spreader again
Agitator motor cable not plugged in
Plug in agitator motor cable
On the display: Slide not open
Slide could not go into position when opening
Check slide for contamination or perform reference
run; see Slide reference run,
Cable not plugged in, motor defective
On the display: Slide not closed
Slide could not go into position when closing
Check slide mechanics for foreign body, or perform
run; see Slide reference run
On the display: Agitator blocking
Agitator motor has excess power consumption
Empty hopper
The version is displayed again and again.
Fuse oxidised, loose contact
Check contacts and fuses
Slide not opening,
Mechanical damage to slide mechanics
Check slide motor and mechanics
no error message displayed
On the display: Connecting spr.
Control panel plug not connected to spreader
Check plug connections and lines
or line damage
Restart machine
Empty indicator does not respond
Empty indicator is set too low
Adjust empty indicator, see page 21
Headline manager closes the slide when draining
Signal incorrectly applied
Change signal. See EHR signal
the hydraulics and opens when lifting
Headline manager does not always close
Distance to magnetic sensor too great
Check distance, max. 10 mm.