12
3 Operating the
MiniVario
®
3.3 Switching on / off
Risk of injury!
The drive motor starts immediately when switched on.
Make sure the danger area is clear when starting.
Press the button.
The speed of the spreading disc and
the slide opening is displayed. The slide
is always closed when switching on the
drive motor.
> Speed
200
Slide
29
If this message is displayed, a cable is damaged
or a plug disconnected.
> Speed
200
Connecting spr.
Low temperatures can cause the empty indicator to respond slowly.
To check the adjustment:
Allow the spreader to run for approx. 1 minute with the slide closed.
If the slide is then opened, the empty indicator must be activated
after approx. 5 seconds.
If this doesn't happen, move the empty indicator 5% into the negative
range; see Settings and displays chapter, Adjusting the empty indicator.
Autostart/automatic freewheeling
If a motor is difficult to start due to heavy loads, start the motor up to
10 times in alternating motor directions. If the mixer or spreading plate
cannot break free as a result, the motor is automatically switched off.
The following message is displayed:
Mixer stationary
, if the mixer cannot break free.
Disc blocking
, if the spreading plate cannot break free.
Содержание MiniVario E
Страница 2: ......
Страница 32: ...30 6 Appendix 6 5 Parts list ...
Страница 34: ...32 6 Appendix 6 5 Parts list ...