Emergency operation
This operation mode is only to be used by trained people such as installers and service
men. This emergency operation allows the platform to be used even if safety circuits are cut
and emergency switches are inactive.
Important: It is necessary that after the unit has been repaired the emergency
operation mode will be disabled!
To activate the emergency operation mode it is necessary to change the Jumper J1 on the
drive unit control to the emergency drive position.
Jumper J1
This jumper controls the operation modus. The following 2 jumper positions are possible.
Please note that no other than these 2 positions can be active, otherwise the board can be
damaged.
Standard operation
Emergency operation
If the jumper J1 was correctly changed then the LD23 should be on. If this is on the platform
can be moved. But the drive commands can only be given from the external control (radio
or hard wired). At the same time as a drive command is given the button S1 has to be
pressed. Both buttons have to be pressed at the same time in order to improve the security
during this operation mode. On the display the error 113 will be shown when the platform
control buttons are pressed.
Important: No security switches are active! The lift will continue driving as long as a
drive command and S1 are pressed simultaneously.