OMEGA
Installation Manual
Edition July 2013
Omega
platform lift
page 26 of 46
Options
Menu item
Parameter
Meaning
Description
Folding
behaviour
ON
Special folding
modus
If this is ON the security circuit on
the drive unit will be checked. If this
is open the unit also will not fold.
OFF
Standard folding
modus
Auto-fold
ON
Automatic closing
ON
If this parameter is ON then the
platform will close automatically
after a defined time if left open in a
landing station.
Attention: Only possible for
automatic and not for manual
platforms
OFF
Automatic closing
OFF
Auto-fold time
seconds
Time to fold
automatically
Defines time lag for auto-fold
Fetch open
ON
Call and send the
platform when
open
If this parameter is on then the
open platform can be call and sent
by the external hall call stations
(when transporting goods)
Attention: This option can only be
chosen if the entire driveway of the
platform is totally visible from the
hall call stations.
OFF
Not permitted
Teach-in mode - Programming the drive speeds
To start the teach drive the platform has to be in the lower landing station.
Now the
menu point „Teach-in start“ can be activated and the LCD display will show the following:
#
At the beginning of the teach-in start 2 points are already saved. The point #P:2 is the
actual point of the lower landing stop. A virtual point #P:1 is required for the counting of the
encoder but does not need to be saved nor to be changed at any time.
Number of the counted point
at beginning of teach-in mode
is always 2
Position count of
the point 2, which is
point at lower
landing