OMEGA
Installation Manual
Edition July 2013
Omega
platform lift
page 9 of 46
Pull back the tension rope inside the upper tube so that it stops where you want to
put the platform onto the rail. The fixing bracket of the tensions rope must be around
800mm above the ground floor level.
Add the current collector into the upper tube next to the fixing bracket. Make sure the
spring between the current collector and the upper fixing bracket is securely
attached to the current collector. This spring is responsible to make the electrical
contact between the tension cable and the platform control board.
Fix spring with
screwdriver on pin
Sliding contacts
connect rail with
control board
(electrical mass)
Pull
back
Upper fixing bracket 800mm
above lower floor level