OMEGA
Installation Manual
Edition July 2013
Omega
platform lift
page 31 of 46
Name
Number
Reaction
Possible reason
Short circuit
between the
support rope and
the rail
15 (F)
Drive only till the
next landing
station, then stop
If there is a short circuit between the
support rope and the rail
SPI Timeout on
drive unit
16 (1.)
Drive is stopped
The communication between the PIC
microcontroller and the Echelon
Powerline module was defunct or not
correctly adjusted.
Safety circuit
17 (2.)
Drive is stopped
Safety circuit relays (KAUF, KAB) on
the platform are not released.
FI-communication 18 (3.)
Only slow drive
possible
The communication with the
frequency inverter via the RS485
Modbus interface did not work.
Communication
with EEPROM on
drive unit
19 (4.)
The communication between the
micro controller and the EEPROM on
the drive unit did not work.
Feedback from
main contactors
20 (5.)
Drive only till the
next landing
station, then stop
One of the main drive contactors or
the safety circuit relay KSK has not
been released after the platform
stopped driving.
Data transfer
between the drive
unit and the
platform control
21 (6.)
Drive is stopped
The communication via the tension
rope did not work correctly. This
failure is detected on the drive unit.
SPI Timeout
Platform
112 (-)
Drive is stopped
The communication between the PIC
micro controller and the Echelon
Powerline module was not correct.
The Powerline module is defect or
not correctly plugged.
Data transfer
between the drive
unit and the
platform control
113 (-)
Drive is stopped
The communication via the tension
rope did not work.
Communication
with EEPROM on
platform
115 (-)
Drive is stopped
The communication of the micro
controller with the EEPROM on the
platform control did not work.