OMEGA
Installation Manual
Edition July 2013
Omega
platform lift
page 19 of 46
The bypass switch S 16 makes an
electrical bridge on the barrier arms safety
switches S14 and S15 and therefore
allows that the lift remains in function
although
the
barrier
arms
are
mechanically unblocked and electrical
safety circuit is interrupted. S16 has to be
activated before the control cams start to
unblock the barrier arms in each landing
station. Otherwise the lift will stop when
the barrier arms are unblocked, as thus
the barrier arm safety switches S14 and/or
S15 are pushed and the safety circuit is
interrupted!
In the upper stop position (and also
intermediate stop positions) the
platform floor should be at the
same level as the landings.
On the lower landing the carriage
should touch down slightly on the
bottom with both buffers located on
the lower end of the backside of the
carriage.
Run the carriage out of the
landings and back again. If the lift
does not stop in the correct
position, adjust it as necessary.
Adjust the ultimate limit
switch so that it is
properly aligned with the
activation pin on the
cover
of
the
upper
carriage. The pin should
reach the switch in case
the normal limit switch
does not work.
Adjust the ultimate
limit switch and
the activation pins!
Activates
by-pass
Activates
limit switch
Deactivates
by-pass
Cam for
unblocking
of barrier
arm
Mechanical
stop assembly
Ultimate
limit switch