Catalogue number(s): 0 484 22
Device power supply
27-50 V
±
/
=
- 6 W
Terminal type
Screw
Number of load terminals
16 outputs
A - B: 2.1 A blocks
{
C - D: 4.3 A blocks
E - F: 16 A blocks
Number of auxiliary input
terminals
16 inputs (G - H: 8-input blocks)
Capacity of the load terminals
2 x 1.5 mm
2
(A to D)
2 x 2.5 mm
2
(E to F)
Capacity of the DALI load
terminals
1 x 2.5 mm
2
Capacity of the auxiliary input
terminals
1 x 2.5 mm²
KNX connection
0.6 to 0.8 mm
2
Contact type
Bistable relay (blocks E & F),
monostable relay (blocks A, B, C
& D)
Location category
Indoor
Degree of protection
Penetration by solid and
liquid matter
IP 20
(installation in an enclosure)
Impact resistance
IK 04
Number of modules
12
Usage temperature
-5°C to +45°C
Storage temperature
-20°C to +70°C
No-load power consumption
< 1 W
KNX/BUS absorption
5 mA
Weight
387 g
Technical data sheet: S000074637EN-5
Updated: 12/03/2015
Created: 15/04/2014
1/29
KNX multiapplication controller 16 outputs
The KNX multi-application modular controller has been specially
designed to meet requirements for control in hotel rooms and meeting
rooms.
It comprises:
•
16 binary outputs that can be configured to control lighting (2 blocks of
4 relays: 4.3 A max. to be distributed in each of the blocks), blinds
(2 blocks of 2 relays: 2.1 A max. to be distributed in each of the blocks)
and power sockets (2 blocks of 2 relays: 16 A max. to be distributed
in each of the blocks). Each output can be part of 5 scenarios and 3
different modes. 4 separate current measurements are incorporated.
• 16 configurable auxiliary inputs for ON/OFF, Dim +/-, scene and raise/
lower/stop commands for roller blinds via switches, pushbuttons or
other volt-free contact devices.
• Functions for creating scenarios and advanced logic functions: 3 logic
“blocks” for sending a command according to 3 conditions and 3
other “program blocks” for sending 5 different actions on 1 command.
1.
USE
2. TEChNiCal fEaTUrES (CONTiNUED)
2. TEChNiCal fEaTUrES
CONTENTS
Page
1. Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
2. Technical features . . . . . . . . . . . . . . . . . . . . . . . .1
3. Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
4. Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5. Operation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
6. Standards and approvals . . . . . . . . . . . . . . . . .6
7. Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
8. Communication objects . . . . . . . . . . . . . . . . . .7
Dali
2 x 1.5 mm
2
Outputs
DALI output
Inputs
2 x 2.5 mm
2
1 x 2.5 mm
2
L
4
3
2
1
L
1
2
3
4
L
1
2
1
2
3
4
8
7
6
5
1
2
1
2
DA DA
12 V
=
128 mA
27-50 V /
Made in France
A
B
C
D
E
L
1
2
F
DALI
G
+
-
H
+
- 1
2
3
4
8
7
6
5
-
+
110/230 V
A
50/60 Hz
6 W
-
+
N
C
N
D
N
E
N
F
0
48
4
22
Power : 27 - 56 V
A
/
=
64 Ballasts max
DALI :
Default
Power
Prog & Reset
A = B =
2,1 A max
C = D =
4,3 A max
E = F =
16A max
12 V
=
12 V
=
60 mA
60 mA
important:
Neutral terminals necessary for:
•
Synchronisation with the mains power supply
•
Measurement of energy consumption
S000074637EN-5.indd 1
20/05/15 10:16