Technical data sheet: S000074637EN-5

Updated: 12/03/2015

Created: 15/04/2014

mber(s): 0 484 22

Catalogue number(s): 0 484 22

KNX multiapplication controller 16 outputs

8. COmmUNiCaTiON OBJECTS (CONTiNUED)

Shutter 2-input

No.

Object name

function

Size

flags

2

(16, 30,

44, 58, 72,

86, 100)

Input G(,H)1 (3

 7)+

G(,H)2 (4

 8)

Shutter Up/

Down

1.008 DPT_

UpDown

CWT

The movement commands Up/Down are sent via the address linked

with this object in order to raise/lower the solar protection.

8

(22, 36,

50, 64, 78,

92, 106)

Input G(,H)1 (3

 7)+

G(,H)2 (4

 8)

Shutter Stop

- slats

1.009 DPT_

OpenClose

CWT

The commands“STOP” or“Slats OPEN/CLOSE” are sent via the group

address linked with this object.

4

(18, 32, 46,

60, 74, 88,

102)

Input G(,H)1 (3

 7)+

G(,H)2 (4

 8)

Enable

1.003 DPT_

Enable

CW

Enable telegrams are received via the group address linked with this

object. They are used to lock (disable) or unlock (enable) the correspon-

ding input.

They are only visible if“Add status object”parameter value is set to yes.

Switch

This function is used for 2 inputs with a switch to send a up,stop or down

telegram : the contact is closed or opened, a telegram is sent.

Parameters

Setting

Xn - Switching value when contact is

closed

No reaction

Up

Down

Here an adjustment is made to define which movement command is

written into the storage cell of the communication object and sent

after a rising edge. The rising edge corresponds to a change in the

signal status at the input from logical “0” to “1”.

“No reaction”: action does not change the object value and also does

not send a telegram.

“Up”: when the contact is active, the command UP is transferred into

the communication object and sent.

“Down

”: when the contact is active, the command DOWN is transferred

into the communication object and sent.

Xn - Switching value when contact is

opened

No reaction

Stop

Here an adjustment is made to define which switching movement

command is written into the storage cell of the communication object

and sent after a falling edge in the signal status at the channel (input).

The falling edge corresponds to a change in the signal status at the

input from logical “1” to “0”.

“No reaction”: action does not change the object value and also does

not send a telegram.

“Stop”: when the contact is inactive, the command stop is transferred

into the communication object and sent.

tion

ng value is written

and sent after short

bject value and also

nary value, “1”) is

t.

nary value ”0”) is

t.

ed in the communi-

tion

ng value is written

and sent after long

the object value and also

y value, “1”) is trans

-

Dim –

tion

ing value is written

and sent after long

the object value and also

ease 100%” is trans-

ease 100%” is trans-

tion

ing value is written

and sent when relea-

the object value and also

er a long push, the dim-

ation object and

ond

ond

onds

ds

ds

ds

ds

detecting a long

ommunication object (sta-

or other purposes.

ormally open contact

y closed contact

o the channel is adjusted here.

t of the input is active when

t of the input is active when

blocked via an additional

f an input is blocked (Enable value = 0) the status

Parameters

Setting

Xn+1 - Switching value when contact

is closed

No reaction

Up

Down

Here an adjustment is made to define which movement command is

written into the storage cell of the communication object and sent

after a rising edge. The rising edge corresponds to a change in the

signal status at the input from logical “0” to “1”.

“No reaction”: action does not change the object value and also does

not send a telegram.

“Up”: when the contact is active, the command UP is transferred into

the communication object and sent.

“Down

”: when the contact is active, the command DOWN is transferred

into the communication object and sent.

Xn+1 - Switching value when contact

is opened

No reaction

Stop

Here an adjustment is made to define which switching movement

command is written into the storage cell of the communication object

and sent after a falling edge in the signal status at the channel (input).

The falling edge corresponds to a change in the signal status at the

input from logical “1” to “0”.

“No reaction”: action does not change the object value and also does

not send a telegram.

“Stop”: when the contact is inactive, the command stop is transferred

into the communication object and sent

Contact type

Normally open contact

Normally closed contact

The contact type of the input attached to the channel is adjusted here.

“Normally open contact”: the contact of the input is active when

closed, inactive when opened.

“Normally closed contact”: the contact of the input is active when

opened, inactive when closed.

add enable object

Yes /

No

The parameter determines if the input can be blocked via an additional

Enable object or not. If an input is blocked (Enable value = 0) the status

changes at this input are not transmitted.

Push

This function is used for 2 inputs with push button to send a up,stop or down

telegram : the push is short or long, a telegram is sent.

S000074637EN-5.indd 17

20/05/15 10:16

Содержание 0 484 22

Страница 1: ...tributed in each of the blocks blinds 2 blocks of 2 relays 2 1 A max to be distributed in each of the blocks and power sockets 2 blocks of 2 relays 16 A max to be distributed in each of the blocks Eac...

Страница 2: ...E and F 2 blocks of 2 relays 16 A max to be distributed in each of the blocks For controlling 2 separate loads per block Each block includes energy measurement Dali output For controlling 64 DALI ball...

Страница 3: ...A Power Supply 27 50 VA 6 W min L N L N L N L N L N L N L N 30 mA L 4 3 2 1 L 1 2 3 4 L 1 2 1 2 3 4 8 7 6 5 1 2 1 2 DA DA 12 V 128 mA 27 50 V Made in France A B C D E L 1 2 F DALI G H 1 2 3 4 8 7 6 5...

Страница 4: ...A 6 A 30 mA 30 mA 30 mA 6 A 10 A 10 A L N L N 30 mA L 4 3 2 1 L 1 2 3 4 L 1 2 1 2 3 4 8 7 6 5 1 2 1 2 DA DA 12 V 128 mA 27 50 V Made in France A B C D E L 1 2 F DALI G H 1 2 3 4 8 7 6 5 110 230 VA 50...

Страница 5: ...30 mA 6 A 10 A 10 A L1 L2 L3 N L1 L2 L3 N L1 L2 L3 N 30 mA L 4 3 2 1 L 1 2 3 4 L 1 2 1 2 3 4 8 7 6 5 1 2 1 2 DA DA 12 V 128 mA 27 50 V Made in France A B C D E L 1 2 F DALI G H 1 2 3 4 8 7 6 5 110 230...

Страница 6: ...ly OFF no fault L 4 3 2 1 L 1 2 3 4 L 1 2 1 2 3 4 8 7 6 5 1 2 1 2 DA DA 12 V 128 mA 27 50 V Made in France A B C D E L 1 2 F DALI G H 1 2 3 4 8 7 6 5 110 230 VA 50 60 Hz 6 W NC ND NE NF 0 484 22 Power...

Страница 7: ...el input The rising edge corresponds to a change in the signal status at the input from logical 0 to 1 No reaction An edge change at the input does not change the object value and also does not send a...

Страница 8: ...the switching value stored in the commu nication object is inverted and the new value is sent Long push action min 0 5 second 1 second 2 seconds 3 seconds 4 seconds 5 seconds 10 seconds This parameter...

Страница 9: ...ine which movement command is written into the storage cell of the communication object and sent after a short press the push button attached to the input No reaction action does not change the object...

Страница 10: ...Scene Number CT The telegrams to recall the scene with the configured number between 1 and 64 are sent via the group address link with this object 4 11 18 25 32 39 46 53 60 67 74 81 88 95 102 109 Inpu...

Страница 11: ...w Priority Off State 01b Low Priority On State 10b High Priority Off State 11b High Priority On State Switch This function is used for inputs with a switch to send a priority telegram the contact is c...

Страница 12: ...4 31 38 45 52 59 66 73 80 87 94 101 108 Input G H 1 2 8 Reset Counter 1 015 DPT_Reset CW If a telegram linked with this object is received then the counter value is reset to the minimum value set by t...

Страница 13: ...tion On Off Toggle Here an adjustment is made to define which switching value is written into the storage cell of the communication object and sent after short pressing the push button attached to the...

Страница 14: ...n ding input They are only visible if Add enable object parameter value is set to yes Parameters Setting Byte value when contact is closed 0 255 1 Here an adjustment is made to define which unsigned 8...

Страница 15: ...to the input Byte value on long push 0 255 0 Here an adjustment is made to define which unsigned 8 bit value is written into the storage cell of the communication object and sent after long pressing...

Страница 16: ...e storage cell of the communication object and sent after short pressing of the push button attached to the input No reaction A short push does not change the object value and also does not send a tel...

Страница 17: ...at the channel input The falling edge corresponds to a change in the signal status at the input from logical 1 to 0 No reaction action does not change the object value and also does not send a telegr...

Страница 18: ...so does not send a telegram Stop the stop command value 1 or 0 is transferred into the com munication object and sent Xn Long push action min 0 5 second 1 second 2 seconds 3 seconds 4 seconds 5 second...

Страница 19: ...t They are used to lock disable or unlock enable the correspon ding input No Object name function Size flags 117 121 125 129 133 137 141 145 149 153 157 161 165 169 173 177 Output Xn 2bits Over ride 2...

Страница 20: ...telegrams are received via the group address linked with this object They are used to lock disable or unlock enable the correspon ding input In ventian blind use you have the parameters for slat cont...

Страница 21: ...at shall be used for the dimmer Attention this value can be overridden by the dali ballast physical minimum level Max Level 0 100 default 100 This parameter is used to set the maximum level that shall...

Страница 22: ...None On or Enable On No Object name function Size flags 198 Mode_Sytem Mode_Sytem 1 010 DPT_ Start CRW 1 Enables System mode disables all other modes 0 No reaction 199 Mode_1 Mode_1 1 010 DPT_ Start C...

Страница 23: ...e order action that should be executed on the output when the corresponding scene number is received Xn n 1 Delay immediate 500 ms 1 second 2 seconds 5 seconds 10 seconds 30 seconds 1 minute 90 s 2 mi...

Страница 24: ...utput 3 4bytes 12 001 DPT_ Value_4_ Ucount The Program function Output 3 value is sent via the address linked with this object when the program is triggered No Object name function Size flags 218 224...

Страница 25: ...ts 1 Byte 2 Bytes 4 Bytes Here it is possible to make an adjustment to set the datapoint size of the Program Fn Output Y XXX communication object Parameters Setting Output 1 2 5 value Type Input Size...

Страница 26: ...Value_2_ Ucount Logic Fn Input 1 4bytes 12 001 DPT_ Value_4_ Ucount This object is used as an event to trigger the logical function Depending on the Input 1 Object size parameter this communication ca...

Страница 27: ...djustment to choose which comparator should be used to compare Value 1 parameter and the value received from the bus Logic Fn Input 1 XXX Attention Due to errors of precision it s strongly recommended...

Страница 28: ...lue 0 15 4 bits Dimming Up 100 Up 50 Up 25 Up 12 Up 6 Up 3 Up 1 Stop Stop Down 1 Down 3 Down 6 Down 12 Down 25 Down 50 1 Byte Non scaled value 0 255 1 Byte Scaled value 0 100 1 Byte Scene 1 64 2 Bytes...

Страница 29: ...elegrams Relay contact On Off On On Off On Off Time delay Off d Delay before OFF delay before ON Switching telegrams Relay contact On Off On On Off On Off Time delay Off On Off e Auto Switch OFF Switc...

Отзывы: