Technical data sheet: S000074637EN-5

Updated: 12/03/2015

Created: 15/04/2014

Technical data sheet

Catalogue number(s): 0 484 22

KNX multiapplication controller 16 outputs

KNX multiapp

2. TEChNiCal fEaTUrES (CONTiNUED)

4.

CONNECTiON

/

/

/

/

M

M

Outputs

A - B

230 V

±

80 VA

0.3 A

250 VA

1.1 A

250 VA

1.1 A

2 (2 x 36) W

0.8 A

80 VA

0.3 A

80 VA

0.3 A

500 W

2.1 A

250 VA

1.1 A

250 VA

1.1 A

110 V

±

40 VA

125 VA

125 VA

1 (2 x 36) W

40 VA

40 VA

250 W

125 VA

125 VA

12 - 48

V

±

/V

=

4-15 VA 0.3 A

13-52

VA

1.1 A 13-52

VA

1.1 A

Outputs

C - D

230 V

±

160 VA

0.7 A

500 VA

2.1 A

500 VA

2.1 A

4 (2 x 36) W

1.7 A

160 VA

0.7 A

160 VA

0.7 A

1000 W

4.3 A

500 VA

2.1 A

500 VA

2.1 A

110 V

±

80 VA

250 VA

250 VA

2 (2 x 36) W

80 VA

80 VA

500 W

250 VA

250 VA

Outputs

E - F

230 V

±

500 VA

2.1 A

1000 VA

4.3 A

1000 VA

4.3 A

10 (2 x 36) W

4.3 A

500 VA

2.1 A

500 VA

2.1 A

3680 W

16 A

500 VA

2.1 A

500 VA

2.1 A

110 V

±

250 VA

500 VA

500 VA

5 (2 x 36) W

250 VA

250 VA

1760 W

250 VA

250 VA

Power supply unit

The device must be powered by an external power supply. Permitted voltage range: 27 to 50 V

A

/

=

, 6 W min.

Power outputs

-Blocks A and B (2 blocks of 2 relays: 2.1 A max. to be distributed in each of the blocks).

For roller blind control functions, exclusive signs (e.g. Do not disturb/Room service) and ON/OFF functions (for AC or DC load).

-Blocks C and D (2 blocks of 4 relays: 4.3 A max. to be distributed in each of the blocks).

For controlling 4 separate loads per block. Each block includes energy measurement.
-Blocks E and F (2 blocks of 2 relays: 16 A max. to be distributed in each of the blocks).

For controlling 2 separate loads per block. Each block includes energy measurement.

Dali output

For controlling 64 DALI ballasts in Broadcast mode. Pairing between the device and the DALI output is not necessary.

The DALI BUS power supply is incorporated in the device. Imax 128 mA/12 V

=

. If I is greater than 128 mA, use an external power supply (remove the

jumpers from the DALI terminals).

Control inputs

- Blocks G and H.

The device has 2 blocks each one having power supply output (12 V

=

) and 8 auxiliary inputs. Switches or pushbuttons can be connected to the

inputs in order to send ON/OFF, dimming, shutter raising/lowering or scenario control commands, their settings can be configured using the ETS

configuration software. The power supply enables the controls to have pilot lights (standby).

1

LED bulbs

2

ELV halogen, compact fluorescent and fluorescent bulbs with separate

electronic ballast

3

ELV halogen, compact fluorescent and fluorescent bulbs with separate

ferromagnetic ballast

4

Fluorescent tubes

5

Compact fluorescent bulbs with built-in electronic ballast

6

Compact fluorescent bulbs with built-in ferromagnetic ballast

7

Halogen bulbs

8

Motors

9

Contactors

• Single phase

1

2

3

4

5

6

7

8

9

3. DimENSiONS

213

83

L

4

3

2

1

L

1

2

3

4

L

1

2

1

2

3

4

8

7

6

5

1

2

1

2

DA DA

12 V

=

128 mA

27-50 V /

Made in France

A

B

C

D

E

L

1

2

F

DALI

G

+

-

H

+

- 1

2

3

4

8

7

6

5

-

+

110/230 V

A

50/60 Hz

6 W

-

+

N

C

N

D

N

E

N

F

0

484

22

Power : 27 - 56 V

A

/

=

64 Ballasts max

DALI :

Default

Power

Prog & Reset

A = B =

2,1 A max

C = D =

4,3 A max

E = F =

16A max

12 V

=

12 V

=

60 mA

60 mA

45

66

50

S000074637EN-5.indd 2

20/05/15 10:16

Содержание 0 484 22

Страница 1: ...tributed in each of the blocks blinds 2 blocks of 2 relays 2 1 A max to be distributed in each of the blocks and power sockets 2 blocks of 2 relays 16 A max to be distributed in each of the blocks Eac...

Страница 2: ...E and F 2 blocks of 2 relays 16 A max to be distributed in each of the blocks For controlling 2 separate loads per block Each block includes energy measurement Dali output For controlling 64 DALI ball...

Страница 3: ...A Power Supply 27 50 VA 6 W min L N L N L N L N L N L N L N 30 mA L 4 3 2 1 L 1 2 3 4 L 1 2 1 2 3 4 8 7 6 5 1 2 1 2 DA DA 12 V 128 mA 27 50 V Made in France A B C D E L 1 2 F DALI G H 1 2 3 4 8 7 6 5...

Страница 4: ...A 6 A 30 mA 30 mA 30 mA 6 A 10 A 10 A L N L N 30 mA L 4 3 2 1 L 1 2 3 4 L 1 2 1 2 3 4 8 7 6 5 1 2 1 2 DA DA 12 V 128 mA 27 50 V Made in France A B C D E L 1 2 F DALI G H 1 2 3 4 8 7 6 5 110 230 VA 50...

Страница 5: ...30 mA 6 A 10 A 10 A L1 L2 L3 N L1 L2 L3 N L1 L2 L3 N 30 mA L 4 3 2 1 L 1 2 3 4 L 1 2 1 2 3 4 8 7 6 5 1 2 1 2 DA DA 12 V 128 mA 27 50 V Made in France A B C D E L 1 2 F DALI G H 1 2 3 4 8 7 6 5 110 230...

Страница 6: ...ly OFF no fault L 4 3 2 1 L 1 2 3 4 L 1 2 1 2 3 4 8 7 6 5 1 2 1 2 DA DA 12 V 128 mA 27 50 V Made in France A B C D E L 1 2 F DALI G H 1 2 3 4 8 7 6 5 110 230 VA 50 60 Hz 6 W NC ND NE NF 0 484 22 Power...

Страница 7: ...el input The rising edge corresponds to a change in the signal status at the input from logical 0 to 1 No reaction An edge change at the input does not change the object value and also does not send a...

Страница 8: ...the switching value stored in the commu nication object is inverted and the new value is sent Long push action min 0 5 second 1 second 2 seconds 3 seconds 4 seconds 5 seconds 10 seconds This parameter...

Страница 9: ...ine which movement command is written into the storage cell of the communication object and sent after a short press the push button attached to the input No reaction action does not change the object...

Страница 10: ...Scene Number CT The telegrams to recall the scene with the configured number between 1 and 64 are sent via the group address link with this object 4 11 18 25 32 39 46 53 60 67 74 81 88 95 102 109 Inpu...

Страница 11: ...w Priority Off State 01b Low Priority On State 10b High Priority Off State 11b High Priority On State Switch This function is used for inputs with a switch to send a priority telegram the contact is c...

Страница 12: ...4 31 38 45 52 59 66 73 80 87 94 101 108 Input G H 1 2 8 Reset Counter 1 015 DPT_Reset CW If a telegram linked with this object is received then the counter value is reset to the minimum value set by t...

Страница 13: ...tion On Off Toggle Here an adjustment is made to define which switching value is written into the storage cell of the communication object and sent after short pressing the push button attached to the...

Страница 14: ...n ding input They are only visible if Add enable object parameter value is set to yes Parameters Setting Byte value when contact is closed 0 255 1 Here an adjustment is made to define which unsigned 8...

Страница 15: ...to the input Byte value on long push 0 255 0 Here an adjustment is made to define which unsigned 8 bit value is written into the storage cell of the communication object and sent after long pressing...

Страница 16: ...e storage cell of the communication object and sent after short pressing of the push button attached to the input No reaction A short push does not change the object value and also does not send a tel...

Страница 17: ...at the channel input The falling edge corresponds to a change in the signal status at the input from logical 1 to 0 No reaction action does not change the object value and also does not send a telegr...

Страница 18: ...so does not send a telegram Stop the stop command value 1 or 0 is transferred into the com munication object and sent Xn Long push action min 0 5 second 1 second 2 seconds 3 seconds 4 seconds 5 second...

Страница 19: ...t They are used to lock disable or unlock enable the correspon ding input No Object name function Size flags 117 121 125 129 133 137 141 145 149 153 157 161 165 169 173 177 Output Xn 2bits Over ride 2...

Страница 20: ...telegrams are received via the group address linked with this object They are used to lock disable or unlock enable the correspon ding input In ventian blind use you have the parameters for slat cont...

Страница 21: ...at shall be used for the dimmer Attention this value can be overridden by the dali ballast physical minimum level Max Level 0 100 default 100 This parameter is used to set the maximum level that shall...

Страница 22: ...None On or Enable On No Object name function Size flags 198 Mode_Sytem Mode_Sytem 1 010 DPT_ Start CRW 1 Enables System mode disables all other modes 0 No reaction 199 Mode_1 Mode_1 1 010 DPT_ Start C...

Страница 23: ...e order action that should be executed on the output when the corresponding scene number is received Xn n 1 Delay immediate 500 ms 1 second 2 seconds 5 seconds 10 seconds 30 seconds 1 minute 90 s 2 mi...

Страница 24: ...utput 3 4bytes 12 001 DPT_ Value_4_ Ucount The Program function Output 3 value is sent via the address linked with this object when the program is triggered No Object name function Size flags 218 224...

Страница 25: ...ts 1 Byte 2 Bytes 4 Bytes Here it is possible to make an adjustment to set the datapoint size of the Program Fn Output Y XXX communication object Parameters Setting Output 1 2 5 value Type Input Size...

Страница 26: ...Value_2_ Ucount Logic Fn Input 1 4bytes 12 001 DPT_ Value_4_ Ucount This object is used as an event to trigger the logical function Depending on the Input 1 Object size parameter this communication ca...

Страница 27: ...djustment to choose which comparator should be used to compare Value 1 parameter and the value received from the bus Logic Fn Input 1 XXX Attention Due to errors of precision it s strongly recommended...

Страница 28: ...lue 0 15 4 bits Dimming Up 100 Up 50 Up 25 Up 12 Up 6 Up 3 Up 1 Stop Stop Down 1 Down 3 Down 6 Down 12 Down 25 Down 50 1 Byte Non scaled value 0 255 1 Byte Scaled value 0 100 1 Byte Scene 1 64 2 Bytes...

Страница 29: ...elegrams Relay contact On Off On On Off On Off Time delay Off d Delay before OFF delay before ON Switching telegrams Relay contact On Off On On Off On Off Time delay Off On Off e Auto Switch OFF Switc...

Отзывы: