Commissioning
Code
Possible Settings
IMPORTANT
No.
Name
Default Selection
P140
(cont)
Relay Output
TB-16, 17
0
11 Local Keypad Control Active
Energizes when the selected source
is active for start control
12 Terminal Strip Control Active
13 Remote Keypad Control Active
14 Network Control Active
15 Standard Reference Active
Energizes when P101 reference is
active
16 Auto Reference Active
Energizes when Auto Reference is
activated using TB-13 input; see
P121...P123
17 Sleep Mode Active
See P240...P242
18 PID Feedback < Min. Alarm
Energizes when PID feedback signal
< P214
19 Inverse PID Feedback < Min.
Alarm
De-energizes when PID feedback
signal < P214
20 PID Feedback > Max Alarm
Energizes when PID feedback
signal > P215
21 Inverse PID Feedback > Max
Alarm
De-energizes when PID feedback
signal > P215
22 PID Feedback within
Min/Max Alarm range
Energizes when PID feedback signal
is within the Min/Max Alarm range;
see P214, P215
23 PID Feedback outside
Min/Max Alarm range
Energizes when PID feedback signal
is outside the Min/Max Alarm range;
see P214, P215
24 Reserved
25 Network Activated
Requires optional communication
module (refer to the network module
documentation).
26 Loss of 0-10V Input
27 Sequencer Controlled
State set in individual sequencer
segments
28 Sequencer Active
29 Sequencer Suspended
30 Sequence Done
End Sequence
31 Actual Speed = 0.0Hz
P142
TB-14 Output
0
0...23 (same as P140)
24 Dynamic Braking
For use with Dynamic Braking option
25...31 (same as P140)