63
Troubleshooting and Diagnostics
5.2
Drive Configuration Messages
When the Mode button is pressed and held, the drive’s display will provide a 4-digit code that
indicates how the drive is configured. If the drive is in a Stop state when this is done, the display
will also indicate which control source commanded the drive to Stop
(the two displays will alternate every second).
Configuration Display
Format = x.y.zz x = Control Source:
L
= Local Keypad
t
= Terminal Strip
r
= Remote Keypad
n
= Network
y = Mode:
S
= Speed mode
P
= PID mode
t
= Vector Torque mode
zz = Reference:
CP
= Keypad
s t
EU
= 0-10 VDC (TB-5)
E1
= 4-20 mA (TB-25)
JG
= Jog
nt
= Network
OP
= MOP
P1...P7
= Preset 1...7
01...16
= Sequencer
Segment
Example:
•
L.S.CP
= Local Keypad Start control, Speed mode, Keypad speed reference
•
t.p.EU
= Terminal Strip Start control, PID mode, 0-10 VDC setpoint reference
•
t.C.12
= Terminal Strip Start control, Sequencer Operation (Speed mode),
Segment #12
•
n.t.p2
= Network Start control, Vector Torque mode, Preset Torque #2 reference
•
n.S.03
= Network Start control, Speed mode, Speed reference from Sequencer
Segment #03
Stop Source Display
Format = x
.StP
L.stp
= Stop command came from Local Keypad
t.stp
= Stop command came from Terminal Strip
r.stp
= Stop command came from Remote Keypad
n.stp
= Stop command came from Network