User Manual PXA125
Programming Reference 4-32
SOURce
Subsystem
This subsystem is used to control output functions, shape and
parameters, frequency, amplitude and amplitude modulation, and filter
type. Optional nodes were omitted from these commands. Factory
defaults after *RST are shown in bold typeface. Parameter low and
high limits are given where applicable.
Keyword
Parameter Form
Default,
Low
Limit,High
Limit
[:SOURce]
:APPLy (?)
:SINusoid (?)
{<freq>,<ampl>,<offs>,<phase>}
:TRIangle (?)
{<freq>,<ampl>,<offs>,<phase>}
:SQUare (?)
{<freq>,<ampl>,<offs>,<duty_cycle>}
:PULSe (?)
{<freq>,<ampl>,<offs>,<delay>,<rise>,<high>,<fall>}
:RAMP (?)
{<freq>,<ampl>,<offs>,<delay>,<rise>,<fall>}
:SINC (?)
{<freq>,<ampl>,<offs>,<N_cycles>}
:EXPonential (?)
{<freq>,<ampl>,<offs>,<exp>}
:GAUSsian (?)
{<freq>,<ampl>,<offs>,<exp>}
:DC (?)
<%_ampl>
:USER (?)
{<seg#>,<sclk>,<ampl>,<offs>}
:FM
(?)
{OFF|ON|0|1}
OFF
:DEViation (?)
<deviation>
1e6,100e-3,100e6
:FUNCtion
:MODE (?)
{FIXed|USER}
FIXed
:SHAPe (?)
{SINusoid|TRIangle|SQUare|RAMP)
SINusoid
:FREQuency
<FM_freq>
1e3,1e-3,100e3
:RASTer (?)
<FM_sclk>
1e6,1e-3,10e6
:TRIGger
:MODE (?)
{CONTinuous|TRIGgered|GATed}
CONTinuous
:SLOPe (?)
{POSitive|NEGative
POSitive
:FREQuency (?)
{<freq>|MINimum|MAXimum}
1e6,100e-6,50e6
:RASTer (?)
{<sclk>|MINimum|MAXimum}
10e6,100e-3,100e6
:SOURce (?)
{EXTernal|INTernal}
INTernal
:FSK (?)
OFF|ON|0|1}
OFF
:FREQuency
:RASTer (?)
<FSK_sclk>
80e6,100e-3,100e6
:MODE (?)
{HOP|RAMP}
HOP
:RAMP
:TIME (?)
<time>
1e-3,10e-6,1
:FUNCTion
:MODE (?)
{FIXed|USER|SEQuence}
FIXed
:SHAPe (?)
{SINusoid|TRIangle|SQUare|PULSe|RAMP
|SINC|EXPonential|GAUSsian|NOISe|DC}SINusoid
:ROCSillator
:SOURce (?)
(INTernal|EXTernal | TCXO)
INTernal
:SWEep (?)
OFF|ON|0|1}
OFF
:STOP (?)
<stop_sclk>
20e6,100e-3,100e6
:TIME (?)
<time>
1e-3,1e-3,1000
:DIRection (?)
(UP|DONW)
UP
:SPACing (?)
(LINear|LOGarithmic)
LINear
:TRIGger
:MODE (?)
{CONTinuous|TRIGgered|GATed}
CONTinuous
:SLOPe (?)
{POSitive|NEGative
POSitive
Содержание PXA125
Страница 14: ...User Manual PXA125 xiv This page intentionally left blank ...
Страница 58: ...User Manual PXA125 2 44 Installation Figure 2 30 Communicating with your Instrument ...
Страница 118: ...User Manual PXA125 3 104 ArbConnection This page intentionally left blank ...
Страница 120: ...User Manual PXA125 Programming Reference 4 2 ...
Страница 161: ...User Manual PXA125 Programming Reference 4 43 ...
Страница 167: ...User Manual PXA125 Programming Reference 4 49 MAXimum 10 in units of volts ...
Страница 179: ...User Manual PXA125 Programming Reference 4 61 ...
Страница 186: ...User Manual PXA125 Programming Reference 4 68 ...
Страница 193: ...User Manual PXA125 Programming Reference 4 75 ...
Страница 208: ...User Manual PXA125 Programming Reference 4 90 This page intentionally left blank ...
Страница 219: ...User Manual PXA125 Specifications A 101 This page intentionally left blank ...