HFP1500 TEST RECORD
Step
Description
Intermediate data
Test Result
Output Zero Voltage
A-5
Output Zero Voltage
(Test limit
≤
± 800 µV)
_____________ V
Offset Accuracy
B-7 Power Supply Negative Output Voltage
________________ V
B-10 Expected Negative Output Voltage
________________ V
B-14 Measured Negative Output Voltage
________________ V
B-16
Offset Error Voltage
(Test limit
≤
± 10.8 mV)
_____________ mV
B-21 Power Supply Positive Output Voltage
________________ V
B-23 Expected Positive Output Voltage
________________ V
B-26 Measured Positive Output Voltage
________________ V
B-28
Offset Error Voltage
(Test limit
≤
± 10.8 mV)
_____________ mV
LF Attenuation Accuracy
C-5 Generator Output Voltage
________________ V
C-6 Expected Output Voltage, top range
________________ V
C-8 Measured Output Voltage, top range
________________ V
C-10
Gain Error
, top range (Test limit
≤
± 1.0%)
_____________ %
C-15 Generator Output Voltage
________________ V
C-17 Expected Output Voltage, mid range
________________ V
C-19 Measured Output Voltage, mid range
________________ V
C-21
Gain Error
, mid range (Test limit
≤
± 1.0%)
_____________ %
###
Содержание HFP1500
Страница 1: ...LeCroy HFP1500 High Frequency Probe Instruction Manual Revision F February 2008 ...
Страница 4: ...iv HFP1500 OM E Rev E BLANK PAGE ...
Страница 18: ...HFP1500 High Frequency Probe 3 8 HFP1500 OM E Rev E BLANK PAGE ...
Страница 22: ...HFP1500 High Frequency Probe 4 4 HFP1500 OM E Rev E BLANK PAGE ...
Страница 26: ...HFP1500 High Frequency Probe 5 4 HFP1500 OM E Rev E BLANK PAGE ...