Transformer

Refer to the graphic below to wire the transformer.

Black

Black

Red

Red

Primary (120V AC)

Secondary (24V AC)

Transformer Schematic

318''

 [78.48mm]

7

8''

 [22.35mm]

218''

 [55.50mm]

134''

 [44.70mm]

258''

 [66.68mm]

214''

 [55.88mm]

0''

 [1.27mm]

Ă

1

8''

 [3.81mm]

138''

 [34.80mm]

214''

 [57.15mm]

178''

 [47.63mm]

134''

 [43.18mm]

Ă

1

8''

 [4.76mm]

1''

 [25.40mm]

334''

 [93.73mm]

TYP

TYP

OPEN STYLE FILAMENT & L.V. RECTIFIER USE 

TRANSFORMERS

DPS switch

Wire the switch as needed for the application.

Set-up

 

L

NOTE: The red dip switches (power supply dip switches) need to be set for 24V.  

 

- Dip switch SW1 should be set to OFF 

 

- Dip switch SW2 should be set to ON

All applications

The restroom kit has two restroom applications built in 

(Mode 7 & 8). The default mode for the restroom kit is Mode 

7 (normally unlocked). Determining which mode is correct 

for you will be based on whether the restroom will be set to 

fail safe (Mode 7) or fail secure (Mode 8). There are three 

LED displays that will allow you to see what mode you have 

selected when advancing through the modes. To change 

the mode of the restroom kit simply press the MENU button 

once and use the UP button to advance to the desired 

mode.

Editing the Settings for a Mode

Typical times are pre-set for lock release and door operator 

activation and is ready to use without changing any 

parameters. If you need to change the timing or delay for an 

output, it can be done by pressing the “MENU” button within 

the mode you selected. Once the option is selected you can 

use the “UP or DOWN” buttons to select the timing needed.

The first option (H & 1 flashing) will be how long relay 1 will 

be activated for (0-50 seconds). The second option (d & 

1 flashing) will be how long to wait before activating relay 

2 (0-15 seconds). The third option (H & 2 flashing) will 

be how long relay 2 will be activated for (0-50 seconds). 

The fourth option (d & 2 flashing) will be how long to wait 

before activating relay 3 (0-15 seconds). The fifth option (H 

& 3 flashing) will be how long relay 3 will be activated for 

(0-50 seconds). See the chart below.

Factory Reset (Defaulting the relay module)

To return the relay module back to its factory default 

settings you will need to remove power, then hold down 

the “MENU” button while powering up the power supply. 

Once started you will see the firmware version listed then 

a number “1” will be displayed. Reconnect your power 

and press the “MENU” button once then use the “UP” or 

“DOWN” button to advance to the desired mode. 
Fully test the operation of the restroom kit for proper 

functionality.

Display (M)

Description (Mode you are in)

Parameters (1-15)

H, then 1

Relay 1 hold time

0.0 to 50 seconds

d, then 1

Relay 2 delay time

0.0 to 15 seconds

H, then 2

Relay 2 hold time

0.0 to 50 seconds

d, then 2

Relay 3 delay time

Depends on mode

H, then 3

Relay 3 hold time

0.0 to 50 seconds

d

Sets the display ON or OFF during operating mode

ON or OFF

A

Input delay on Activate. If other than 0.0 is selected, the input must be held 

in for the time period chosen before the relay module will activate.

0.0 to 10 seconds

1

Set Dry Input 1 to activate on normally open or normally closed contact.

N/O or N/C

2

Set Dry Input 2 to activate on normally open or normally closed contact.

N/O or N/C

3

Set Dry Input 3 to activate on normally open or normally closed contact.

N/O or N/C

4

Set Dry Input 4 to activate on normally open or normally closed contact.

N/O or N/C

5

Not used.

Not used

Содержание 8310-2420

Страница 1: ...for Door to Close vinyl decal 1 9 Door locked when red unlocked when green black vinyl sign 1 10 Door occupied when red vacant when green black vinyl sign 1 11 E strike with 3 faceplates and hardware...

Страница 2: ...B2 Power 50 VA DPS Switch Descriptions 8310 2420 Series Power max 3 0 W Electrical configuration SPDT Suggested Wiring 22AWG Gap distance max 0 75 Operation at a glance When the exterior PUSH TO OPEN...

Страница 3: ...onic board in place 1e Place the diffuser insert inside the flush enclosure making sure the mounting screw holes on the diffuser insert and the flush enclosure align For Push to Open switches a Use th...

Страница 4: ...Safe mode when Mode Selector is pointing to FS Fail Lock mode when Mode Selector is pointing to Fail Lock Set Screw Mode Selector Mode Selector Set Screw L Note The products are intended to be instal...

Страница 5: ...r The transformer should only be installed OUTSIDE of the Power Supply Cabinet per all National Electric Code NEC NFPA 70 requirements along with local code requirements and it should be kept in close...

Страница 6: ...ently off Do not wire the primary terminals of the transformer until the secondary terminals are connected first The supplied transformer will have its secondary terminals wired to the terminals red w...

Страница 7: ...ls in cabinet via wire access hole RED GREEN BLUE Connected to 24V DC from the VDC terminals in the cabinet via wire access hole REM LOC RELAY SPEAKER Wired to the Inside Push to Open terminals in the...

Страница 8: ...0 50 seconds The second option d 1 flashing will be how long to wait before activating relay 2 0 15 seconds The third option H 2 flashing will be how long relay 2 will be activated for 0 50 seconds T...

Страница 9: ...2 3 ON DP RED GREEN BLUE REM LOC RELAY SPEAKER See the diagrams below for the dip switch functionalities Enable Dip Switch Bank Idle COL Dip Switch Bank Switch number Description Switch number Descrip...

Страница 10: ...K THIS DOOR WAIT FOR DOOR TO CLOSE Place sign on the door inside the restroom at eye level INSIDE THE RESTROOM POWER SUPPLY 6 12 24 VDC SMP3 24V OPEN CLSD CLSD OPEN SW1 SW2 6V OPEN OPEN 12V SW1 SW2 AC...

Страница 11: ...shown connecting the Push to Open switch to the Push to Open terminals Com Rem PBTN N O Pwr AC DC Com Rem PBTN N O Pwr AC DC IMPORTANT Ensure wiring polarity is consistent from Relay 3 to each remote...

Страница 12: ...osing the door or after pushing Push to Lock Logic Module not in Mode 7 Change Logic Module to Mode 7 and ensure all mode 7 settings are set as shown in the instructions No power to the strike Ensure...

Страница 13: ...he solenoid releases This can be caused by too much stack pressure on the door pressing on the strike Electric Strike itself is set to Fail Secure rather than Fail Safe Follow the electric strike inst...

Страница 14: ...is latching then the door may not fully latch If this occurs the source of the pressure force needs to be removed so that the door can fully close This can be caused by too much stack pressure preven...

Страница 15: ...inals Take a jumper wire and touch the screw heads of the PBTN and terminals the actuators wires are hooked up to If the unit acts as if the actuator was actually pushed then either the actuator was w...

Страница 16: ...ion DPS switch not closing contact Wiring issue Verify wiring is correct to Power Supply Relay Cabinet and DPS wires fully connected Incorrect mounting Mounting gap should be no more than 3 4 between...