- 14 -
ALIBI MEMORY (ONLY FOR INSTRUMENTS WHERE THIS OPTION IS AVAILABLE)
The instrument automatically saves the weight in the alibi memory during the lorry entry or exit operations.
If the net function is active, the net weight is stored; otherwise, the gross weight is stored.
Saving to the alibi memory is only possible if:
-
the alibi memory is enabled;
-
the weight is stable;
-
the weight is above the minimum weight (20 e);
-
the weight is below the max capacity;
-
the weight has changed since the latest storage to alibi (see section
WEIGHINGS STORAGE
AND PRINTING CONDITIONS
);
An identifying number is automatically assigned to each record stored in the memory, it increases
for stored records from 1 to 999999, and is automatically reset to 1 after reaching 999999.
The alibi memory is used in a “circular” manner: when the memory end is reached, the sys
tem will
restart from the memory beginning by overwriting the first record; an alarm message is displayed
(
).
ALIBI MEMORY READING
(identification): enter the ID number of your required record and confirm, the display will show:
-
Gross weight (
) or net weight (
); confirm with ENTER;
-
Tara weight (
) or preset tare (
), only if the recalled weight is a net weight; confirm
with ENTER;
The parameter provides the ID of the last record stored in Alibi Memory by default.
If the entered identifier does not match any record, the message
is displayed.
+