- 33 -
SINGLE WEIGHING USING THE DATABASE
-
The tractor goes onto the weighbridge.
Press DB, the display shows
.
With the numerical keypad enter the database index associated to the tractor (the weight of the
empty tractor and trailer must have already been entered previously in the database in two
separate indexes, see section
LORRY DATABASE
).
Press ENTER.
The instrument applies the preset tare read from the database and shows the weight of the
material loaded onto the tractor (net weight).
Hold the IN key pressed if the lorry is entering (the material will be unloaded),
appears
(Trailer = it indicates the t trailer function), press ENTER.
Hold the OUT key pressed if the lorry is leaving (the material has been loaded),
appears
(Trailer = it indicates the t trailer function), press ENTER.
The instrument saves the weighed value in the memory and shows
(printing takes place
after the subsequent weighing of the trailer).
-
The trailer goes onto the weighbridge.
Press DB, the display shows
.
With the numerical keypad enter the database index associated to the trailer.
The instrument applies the preset tare read from the database and shows the weight of the
material loaded onto the trailer (net weight).
Press IN if the lorry is entering (the material will be unloaded).
Press OUT if the lorry is leaving (the material will be loaded).
The display shows the weight of the material preceded by the letter
for “Unloaded” if unloaded,
letter
for “Loaded” if loaded.
The instrument saves the weighed value in the memory and sends it for printing.
The instrument automatically goes back to showing the gross weight.
To cancel the weighing press ESC.
NOTES:
operation with single weighing is only possible with the net weight. The totals are updated
every time a weighing is completed. To display, print or delete the totals, see sections
TOTALS
and
PRINTING EXAMPLES
.
The conditions that allow a new weighing to be carried out can be set (see section
WEIGHINGS
STORAGE AND PRINTING CONDITIONS
).