- 55 -
POSSIBLE COMMANDS TO BE SENT TO THE COMMAND REGISTER (40006)
0
No command
1
6
7^
SEMI-AUTOMATIC TARE enabling
(net weight displaying)
8
SEMI-AUTOMATIC ZERO
9
SEMI-AUTOMATIC TARE disabling
(gross weight displaying)
20
21
Keypad lock
22
Keypad and display unlock
23
Keypad and display lock
98
99
Save data in EEPROM
110
Weight storage in alibi memory
111
Alibi memory value reading
130^
Preset tare enabling
131
^)
Command not available if net functions are disabled (see parameter
in section
INFO
MENU
).
If it is necessary to execute the same command twice consecutively, send command 0
between the first command and the following one.
ALIBI MEMORY OPERATION CONTROLS
SAVING A WEIGHT IN ALIBI MEMORY
To save a weight in alibi memory send the command 110 to the Command Register. If the operation is
successfully completed, the “Alibi memory identification number” register
(40082 - 40083) increases
and the stored values can be read in the 40084 ÷ 40090 registers; see the next section for more
information about these registers. If printing is enabled, the stored weight value will be printed.
The alibi memory is used in a circular mode: once reached the memory end, the system starts from
the beginning by overwriting the first record; the
“
Alibi memory overwrite
”
bit of the Status Register is
enabled until the following saving in the alibi memory.