CHAPTER 4
OPERATION
4-15
DN-107P displays series
4.3.8.
Function 15. Tachometer with the less significant digit = 0.
The function 15 has the same working as the function 5 but the digit of less weight is always 0.
Example:
Value of the frequency without correction = 145
Shown value = 140
4.3.9.
Function 25. Tachometer with the 2 less significant digit = 0.
The function 25 has the same working as the function 5 but the two digits of less weight are
always 0.
Example:
Value of the frequency without correction = 145
Shown value = 100
4.3.10.
Function 6. Binary.
The function 6 permit display a 9 bits binary value in decimal format.
Value 0 is shown with all inputs OFF and value 512 is shown with all inputs ON.
The parameter A. Pu allows configuring the decimal point position.
4.3.11.
Parameter 7. Digit by digit
Function 7 allows the user to modify every digit independently using an input.
If the display has more than 7 digits, each of the inputs increments one digit. On the
other side, inputs 1 to 7 allow incrementing digits and 8 to 14 decrement digits
Digit one is the one on the far right of the display.
The decimal point cannot be configured.
Input
Function
E1
Incr. Digit 1
E2
Incr. Digit 2
E3
Incr. Digit 3
E4
Incr. Digit 4
E8
Decr. Digit 1
E9
Decr. Digit 2
E10
Decr. Digit 3
E11
Decr. Digit 4