CHAPTER 4
OPERATION
4-7
DN-107P displays series
4.2.6.5.
Parameter 6Pd: Number of decimals.
Selects the maximum number of decimal positions. If there isn’t enough space to show
all the integers numbers, the number of decimal positions will automatically decrease.
The possible values are: 0, 1, 2, 3, 4 and 9. A value of 9 indicates that there will be used
as many decimal positions as possible.
4.2.6.6.
Parameter 7.FA: Average factor.
Selects the number of samples that are used to do an average and reduce the changes.
When the input frequency has a big
change and you don’t want to see it, the average factor
reduces the change.
Each time that the data is updated, the new number erase the oldest. The possible
values are from 0 to 9. The number of samples are the average factor multiplied 5.
4.2.6.7.
Parameter B. So: Exit modify parameters.
In order to exit the sequence for modifying parameters, select the last parameter in the
menu. Then press "*".
See the input wiring and examples in 4.3.7
4.2.7.
Parameters of function 06 (Binary)
4.2.7.1.
Parameter A. PU: Decimal points
Selects the decimal point position (the number of decimal digits). With a value of 0 no
decimal digits will be shown.
4.2.8.
Parameters of function 07 (Digit by digit)
Function 07 has no parameters, excepting in displays with colour or serial line options.