4-4
OPERATION
CHAPTER 4
Display series DN-107P
4.2.4.8.
Parameter 9. FA: Value of the multiplying or splitter factor
Is the value at which the counter will be increased or decreased at each new impulse. It
can be programmed from the value 0.001 to 9999 (4 digit displays) and 0.01 to 999 (3 digit
displays.
The display behaves a multiplier for factors greater than 1 and a divisor for less than 1.
The position of the point is adjusted after modifying the last digit on the right (No digit
flashes), Press the + key to move the position of the point.
4.2.4.9.
Parameter A. PU: Decimal point
Selects the decimal point position (the number of decimal digits). With a value of 0 no
decimal digits will be shown.
4.2.4.10.
Parameter B. So: Exit modify parameters.
In order to exit the sequence for modifying parameters, select the last parameter in the
menu. Then press "*".
See the input wiring and examples in 4.3
4.2.5.
Parameters of function 04 (Chronometer).
The chronometer format and its maximum value
depends on the display’s digit number:
3 Digits display: D.DD
Maximum value: 9.59
4 Digits display: DD.DD
Maximum value: 99.59
These displays can be configured to count hours/minutes or minutes/seconds.
Parameter 2. Co: Control of Hours-Minutes or Minutes-Seconds, increase/decrease
and function preset.
Parameter 3. P1: Value of preset 1.
Parameter 4. P2: Value of preset 2.
Parameter 5. A1: Value of alarm 1.
Parameter 6. A2: Value of alarm 2.
Parameter 7. S1: Activation and temporization conditions of output 1.
Parameter 8. S2: Activation and temporization conditions of output 2.
Parameter F. in: Exit programming parameters.