DN-107P displays series
4.2.5.1.
Parameter 2. Co
This is a 2 digit parameter. The function of each digit is indicated in the following table.
Left digit
Operating modes
Right
digit
Automatic function
0
Increase Hours/Minutes
0
Not activated
1
Decrease Hours/Minutes
1
Time = Alarm 1
→ Reset
2
Inc/Dec Hours/Minutes
→
Input 5
2
Time = Alarm 2
→ Reset
3
Increase Minutes/Seconds
3
Time = Alarm 1
→ Preset 1
4
Decrease Minutes/Seconds
4
Time = Alarm 2
→ Preset 1
5
Inc/Dec
Minutes/Seconds
→ Input 5
5
Time = Alarm 1
→ Preset 2
6
Time = Alarm 2
→ Preset 2
7
Time = Alarm 1
→ Stop
8
Time = Alarm 2
→ Stop
In types of working 2 and 5 (Inc./Dec. Hours/Min.
→ input 5 and Inc./Dec. Min./Sec. →
input 5) the time is increased or decreased depending on the state of input5.
With the input 5 activated, the time increases. With the input 5 deactivated, the time
decreases.
The automatic function (right digit) permits modifying the stopwatch.
0
Chronometer value not modified.
1
Resets the chronometer if it is equal to alarm 1
2
Resets the chronometer if it is equal to alarm 2
3
Loads preset 1 if it is equal to alarm 1
4
Loads preset 1 if it is equal to alarm 2
5
Loads preset 2 if it is equal to alarm 1
6
Loads preset 2 if it is equal to alarm 2
7
Stops the chronometer if it is equal to alarm 1
8
Stops the chronometer if it is equal to alarm 2
4.2.5.2.
Parameter 3. P1: Preset 1 value
The maximum value is 23h:59m or 59m:59s.
4.2.5.3.
Parameter 4. P2: Preset 2 value
The maximum value is 23h:59m or 59m:59s.
4.2.5.4.
Parameter 5. A1: Alarm 1 value
The maximum value is 23h:59m or 59m:59s.
4.2.5.5.
Parameter 6. A2: Alarm 2 value
The maximum value is 23h:59m or 59m:59s.
4.2.5.6.
Parameter 7. S1: Activation and temporization conditions of output 1.