Solution
Cause
Problem
•
Rapid wear of Venturi diffuser
•
The powder puffs out of the spray
gun
•
Insufficient powder flow
•
The powder is not sufficiently
electrostatically charged and/or
does not “cover”
•
The powder "cover" but the µA
scale does not increase
•
No mains voltage;
•
Worn or partially clogged Venturi;
•
The additional air pressure is exces-
sive (rack central regulator) or the
ratio between this and the powder
delivery air pressure is incorrect (left
rack regulator);
•
The tank's fluid bed air pressure is
excessive or insufficient;
•
The unidirectional valves of the pow-
der pump are partially clogged;
•
Powder passage tube too short or
with excessive inner diameter;
•
The air pressure for adjusting the
powder delivery is insufficient;
•
The powder is too wet and is sucked
up by the powder pump with difficulty;
•
Worn or partially clogged Venturi;
•
The additional air pressure (central
regulator rack) is excessive;
•
The additional nozzle cleaning air
pressure is excessive;
•
The piece to be painted is not properly
electrically grounded;
•
The powder is not suited for use with
a corona and/or triboelectric system;
•
Only for triboelectric spray gun:
•
The "tribo" air pressure (central
regulator rack) is excessive;
•
For CH 200 spray gun: nozzle dam-
aged and/or dirty;
•
For triboelectric spray gun: charge
tube dirty and/or damaged;
•
Display board not working;
•
For triboelectric spray gun: tribo-
corona switch set to"corona";
•
Use a hard metal Venturi diffuser
(code 5296/A);
•
Clean and/or replace the Venturi;
•
Decrease the additional air pres-
sure and/or increase the powder
delivery air pressure.
Important:
The additional air pres-
sure must always be lower than the
powder delivery air pressure;
•
Adjust the fluid bed air pressure
(recommended pressure value:
0.5-1bar);
•
Clean and/or replace the unidirec-
tional valves;
•
Use the powder passage tube
supplied or a tube with an inner
diameter that is no greater than
12mm and with a length no less
than 5 metres;
•
Increase the air pressure to adjust
powder delivery;
•
Check the compressed air supply
line. Install an air dryer if necessary;
•
Clean and/or replace the Venturi;
•
Decrease the additional air pres-
sure;
•
Decrease the additional air pres-
sure;
•
With a tester or similar instrument
check the electrical grounding of
the piece holder hooks. If neces-
sary, clean the piece holder hooks;
•
Consult the powder supplier;
•
Increase the "tribo" air pressure to
increase the triboelectric effect;
•
Clean and/or replace the nozzle;
•
Clean and/or replace the charge
tube;
•
Replace the display board;
•
Move the switch to "tribo";