Edit. 03 - 06/2019
www.larius.eu
CH 200 AD
16
I
Gun CH 200
Tribo-electric gun
EVERY 40 - 80 HOURS AND/OR AT EVERY COLOUR CHANGE
Cleaning the powder supply tube
• Disconnect the powder supply tube (
I4
) from the tank
and spray gun and blow in compressed air to remove any
remaining powder residue.
Ensure the powder passage tube is not cracked, bent or
damaged in any way.
CYCLICAL ROUTINE MAINTENANCE
EVERY 8 HOURS AND/OR AT EVERY COLOUR CHANGE
Cleaning the CH200 spray gun
• Disconnect the powder supply tube and remove the nozzle
(
I1
) of the spray gun.
• Clean the inner part of the spray gun and nozzle with a jet
of compressed air. If necessary, use the brush supplied to
clean the spray gun.
Before performing any maintenance or cleaning operation disconnect the electric and pneumatic power supply.
Cleaning the triboelectric spray gun
• Disconnect the powder supply tube and remove the noz
-
zle. Clean the inner part of the spray gun and nozzle with
a jet of compressed air.
•
If removing the triboelectric spray gun is necessary
Using your hands, unscrew the charge tube (
I2
) from the
spray gun body. Using your hands, slip off the diffuser (
I3
).
Remove the nozzle.
I4
I1
I2
I3