Appendix A: Command Reference
xPico® Wi-Fi® Embedded Device Server User Guide
90
value Timeout
Sets the
Timeout
to receive response. Minimum timeout is 100 milliseconds.
Response is ended by any configured
End Character
,
Length
OR
Timeout
.
Timeout
has units of milliseconds.
Blank the value for "<Minimum>".
configgroup Monitor Poll
These settings pertain to
Monitor Poll
in the device.
Poll Message will be processed periodically. Response will overwrite any response captured during
initialization or poll.
configitem Message
value Command
Sets the
Command
in binary format.
Binary format takes printable characters (e.g. 'abc' for characters 'a', 'b' and 'c') or binary string (e.g. [0xa,
0xd] for line feed and carriage return).
Command
may contain up to 16 bytes.
value End Character
Sets the
End Character
to indicate end of response.
Response is ended by any configured
End Character
,
Length
OR
Timeout
.
The
End Character
may be designated as a single printable character or as a control character.
Control characters may be input in any of the following forms:
<control>J
0xA (hexadecimal)
\10 (decimal)
End Character
may contain one character, where <control>J, for example, counts as one.
value Length
Sets the
Length
of response.
Response is ended by any configured
End Character
,
Length
OR
Timeout
.
Length
has units of bytes.
value Timeout
Sets the
Timeout
to receive response. Minimum timeout is 100 milliseconds.
Response is ended by any configured
End Character
,
Length
OR
Timeout
.
Timeout
has units of milliseconds.
Blank the value for "<Minimum>".
configitem Delay
value
Sets
Delay