9: Device Ports
SLC™ 8000 Advanced Console Manager User Guide
159
To set up Telnet, SSH, and TCP port numbering:
1. Enter the following:
Telnet/SSH/TCP in Port Numbers
Caution:
Ports 1-1024 are RFC-assigned and may conflict with services running
on the SLC 8000 advanced console manager. Avoid this range.
2. Click the
Apply
button to save the settings.
To set limits on direct connections:
1. Enter the maximum number (1-10) of simultaneous direct connections for each device port.
The default is 1.
2. Click the
Apply
button to save the settings.
To configure a specific port:
1. You have two options:
-
Select the port from the ports list and click the
Configure
button. The
-
Click the port number on the green bar at the top of each page.
2. Continue with directions in the section,
Device Ports - Settings (on page 160)
DevicePort Global Commands
Go to
to view CLI commands which correspond to the web page entries
described above.
Starting Telnet Port
Each port is assigned a number for connecting via Telnet. Enter a number (1025-
65528) that represents the first port. The default is 2000 plus the port number. For
example, if you enter 2001, port 1 will be 2001 and subsequent 2000 ports are
automatically assigned numbers 2001, 2002, and so on.
Starting SSH Port
Each port is assigned a number for connecting via SSH. Enter a number (1025-
65528) that represents the first port. The default is 3000 plus the port number. For
example, if you enter 3001, port 1 will be 3001 and subsequent 3000 ports are
automatically assigned numbers 3001, 3002, and so on.
Starting TCP Port
Each port is assigned a number for connecting through a raw TCP connection. Enter
a number (1025-65528) that represents the first port. The default is 4000 plus the
port number. For example, if you enter 4001, port 1 will be 4001 and subsequent
4000 ports are automatically assigned numbers 4001, 4002, and so on.
You can use a raw TCP connection in situations where a TCP/IP connection is to
communicate with a serial device. For example, you can connect a serial printer to a
device port and use a raw TCP connection to send print jobs to the printer over the
network.
Note:
When using raw TCP connections to transmit binary data, or where the break
command (escape sequence) is not required, set the Break Sequence of the
respective device port to null (clear it).
Содержание SLC 8000 Series
Страница 1: ...Part Number 900 704 R Revision R November 2019 SLC 8000 Advanced Console Manager User Guide ...
Страница 72: ...6 Basic Parameters SLC 8000 Advanced Console Manager User Guide 72 Figure 6 2 Network Network Settings 2 of 2 ...
Страница 88: ...6 Basic Parameters SLC 8000 Advanced Console Manager User Guide 88 Figure 6 7 Network VPN 1 of 2 ...
Страница 149: ...8 USB SD Card Port SLC 8000 Advanced Console Manager User Guide 149 Figure 8 4 Devices USB Modem ...
Страница 174: ...9 Device Ports SLC 8000 Advanced Console Manager User Guide 174 Figure 9 8 Device Ports RPMs Add Device ...
Страница 313: ...13 Maintenance SLC 8000 Advanced Console Manager User Guide 313 Figure 13 12 About SLC ...