7: Services
SLC™ 8000 Advanced Console Manager User Guide
142
run on the SLC. When the client starts, it will request all probes and scripts that are defined to
run on the SLC. The status of the probes and scripts is displayed in the
Status of Client
.
When a script run completes (either for a single manual run or a recurring scheduled run), the
status of the script will be retained on the SLC until a new script is initiated from ConsoleFlow
and the SLC determines that the maximum number of ConsoleFlow scripts per SLC has been
reached; at this time the oldest completed script will be deleted to accommodate the new
script.
Note:
If a script is initiated from ConsoleFlow to run on multiple ports on the SLC,
each script/port combination is a separate script "instance", and is counted separately
in the total number of scripts running on the SLC.
7. Managed Device Connection Status Digital Probes
The primary method for determining the ConsoleFlow Managed Device Connection Status is
by reading the DSR status for the device port. For serial devices that do not set DSR, a digital
probe can be enabled which will periodically send a newline (\n) character to the device, and
the SLC will verify if a response is received from the device within approximately one second.
If a response is received, the Managed Device will be set to Connected; if no response is
received, the Managed Device status will be set to Disconnected. This feature is disabled by
default for all device ports, and can be enabled for individual device ports via the CLI (the
frequency that the newline character is sent can be configured). Digital probes that are
enabled will only run while the ConsoleFlow client is running. If a digital probe is enabled for a
device that has set DSR, the digital probe will still run, but the results from the digital probe will
be ignored when determining the Managed Device Connection Status.
Note:
(a) the digital probe is an intrusive feature and can affect actions on the
Managed Device, depending on what is happening on the Managed Device or what
users are connected to the Managed Device when the newline character is sent; (b)
Managed Devices may not generate a response to the newline character within
approximately one second, and this may result in the Managed Device Connection
Status being set to Disconnected.
8. CLI Commands
CLI commands can be issued to a set of console managers from ConsoleFlow. CLI
commands which require user input for a confirmation or prompt, or require some other user
interaction ('connect direct' or diag commands) are not supported. Abbreviated commands are
also not supported (e.g., "show network all" is supported, but "sh ne all" is not supported).
To configure ConsoleFlow settings:
1. Click the
Services
tab and select the
ConsoleFlow
option. The following page displays.
Содержание SLC 8000 Series
Страница 1: ...Part Number 900 704 R Revision R November 2019 SLC 8000 Advanced Console Manager User Guide ...
Страница 72: ...6 Basic Parameters SLC 8000 Advanced Console Manager User Guide 72 Figure 6 2 Network Network Settings 2 of 2 ...
Страница 88: ...6 Basic Parameters SLC 8000 Advanced Console Manager User Guide 88 Figure 6 7 Network VPN 1 of 2 ...
Страница 149: ...8 USB SD Card Port SLC 8000 Advanced Console Manager User Guide 149 Figure 8 4 Devices USB Modem ...
Страница 174: ...9 Device Ports SLC 8000 Advanced Console Manager User Guide 174 Figure 9 8 Device Ports RPMs Add Device ...
Страница 313: ...13 Maintenance SLC 8000 Advanced Console Manager User Guide 313 Figure 13 12 About SLC ...