TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
BURNER WILL
NOT LIGHT
(Continued from
previous page)
Fuel not reaching
combustion chamber
Check fuel pump for proper flow. Check
solenoid flow switch on machines with spray
gun control, for proper on-off fuel flow control.
Clogged burner nozzle
Clean as required.
Thermostat faulty or slow engine
speed
Increase engine RPM to increase voltage.
Flow switch malfunction
Remove, test for continuity and replace as
needed.
Flow solenoid malfunction
Replace if needed.
FLUCTUATING
PRESSURE
Valves worn
Check and replace if necessary.
Blockage in valve
Check and replace if necessary.
Pump sucking air
Check water supply and air seepage at joints in
suction line.
Worn piston packing
Check and replace if necessary.
Gasoline Engine Altitude
The gasoline engine is preset for operation at
altitudes below 1000 feet above sea level. If
operated at higher altitudes, it may be neces-
sary to install a high altitude main jet in the
carburetor. Contact your local authorized
engine sales and service center for details.
MACHINE
SMOKES
Improper fuel or water in fuel
Drain tank and replace contaminated fuel.
Improper air adjustment
Readjust air bands on burner asssembly.
Low fuel pressure
Adjust fuel pump pressure to specifications.
Plugged or dirty burner nozzle
Replace nozzle.
Faulty burner nozzle spray pattern
Replace nozzle.
Heavy accumulation of soot on coils
and burner assembly
Remove coils and burner assembly, clean
thoroughly.
Obstruction in smoke stack
Check for insulation blockage or other foreign
objects.
Low engine RPM
Increase RPM.
LOW WATER
TEMPERATURE
Improper fuel or water in fuel
Replace with clean and proper fuel.
Low fuel pressure
Increase fuel pressure.
Weak fuel pump
Check fuel pump pressure. Replace pump if
needed.
Fuel filter partially clogged
Replace as needed.
Soot build-up on coils not allowing
heat transfer
Clean coils.
Improper burner nozzle
See specifications.
WATER
TEMPERATURE
TOO HIGH
Incoming water to machine warm or
hot
Lower incoming water temperature.
Fuel pump pressure too high
See specifications for proper fuel pressure.
Fuel pump defective
Replace fuel pump.
Detergent line sucking air
Tighten all clamps. Check detergent lines for
holes.
Defective temperature switch
Replace.