![Land 4500 MKII Premier Скачать руководство пользователя страница 122](http://html1.mh-extra.com/html/land/4500-mkii-premier/4500-mkii-premier_operation-and-maintenance-manual_3476555122.webp)
Model 4500 Premier Dust and Opacity Monitor
122
Environmental
Operating temperature:
-20 to 55
o
C / -4 to 131
o
F
(-40
o
C / -40
o
F with optional heater)
Maximum Flue Gas temperature: 600
o
C / 1112
o
F
Maximum Flange Temp:
200
o
C / 392
o
F
Environmental rating:
IP66 / NEMA4X
Compliance
Measurement standards:
Meets or exceeds US EPA requirements for 40CFR60
Sections 13, 17 and App. B PS1
Meets or exceeds US EPA requirements for proposed
40CFR60 App. F Procedure 3
Meets or exceeds ASTM Standard D6216 - 98
Meets or exceeds US EPA CPS-001
Safety:
Conforms to EN-61010-2
EMC:
Conforms to E-50 081 & EN-50 082
Outputs
Modbus Interface:
RS232 or RS485. Opacity, Dust, Optical Density, Status,
Averaging and Range information available
Analogue Outputs:
Two isolated 4-20mA current outputs.
Independently configurable as Opacity, Dust Optical Density,
Calibration Drift or PLCF
Relay Outputs:
System OK, Span calibration, Zero calibration, Alarm 1,
Alarm 2, Maintenance