5
8. Reattach Drip Tray/Cup Rest to unit.
Drain line must be insulated with a closed cell
insulation. Insulation must cover the entire length of
the drain hose, including fittings. The drain should be
installed in such a manner that water does not collect
in sags or other low points, as condensation will form.
!
CAUTION
Pouring hot water down the drain may cause the Drain
Tube to collapse. Allow only luke warm or cold water to
enter the Drain Tube.
Pouring coffee, tea, or other
similar substances down the drain may cause the Drain
Tube to become clogged.
!
ATTENTION
A
A. Drain Fitting
B. Drain Line
C. Drip Tray
B
C
Remote Pump Installation
1. If necessary, install water booster (Lancer PN MC-163172)
between water supply and the unit.
2. Using tubing cutters, cut water line and install tee fitting, then
route appropriate tubing from the remote pump location to
the tee fitting at water line.
A
B
C
D
A. Tee Fitting
B. Line to Plain Water Inlet
C. Line to Water Source
D. Line to Remote Pump
3. Connect line from tee fitting at water line to the remote pump
deck inlet regulator.
4. Complete the carbonated water line connection between the
remote pump deck and carbonated water inlet on the unit.
A
B
C
A. Oetiker Pliers
B. Line to Tee Fitting
C. Pump Inlet
D. Pump Outlet
D
5. Install a shut-off valve in the water line feeding the deck. If a
separate water line is run for plain water, ensure that it also
has a shut-off valve.
A
A. Oetiker Pliers C. Pump Inlet
B. Line to Unit
D. Pump Outlet
B
C
D
Installing Remote Syrup Pumps
1. Install BIB rack and remote pumps according to
manufacturers’ instructions.
2. Once pumps and BIB rack are installed, measure and cut
tubing to length between the pump CO
2
inlets, then connect
tubing to all pumps.
A
B
C
A. Syrup Pump
B. CO
2
Line
C. Fitting
D. Oetiker Pliers
D
3. Using tubing cutters, cut any pump CO
2
supply line and
install tee fitting, then route appropriate tubing from the CO
2
supply to the tee fitting at syrup pumps.
4. Connect tubing from dispenser syrup inlet to the syrup pump
outlet fitting. Repeat for each syrup line/pump.
A
B
C
A. Syrup Pump Outlet
B. Syrup Pump
C. Fitting