background image

5

8.  Reattach Drip Tray/Cup Rest to unit.

 

Drain line must be insulated with a closed cell 

 

insulation. Insulation must cover the entire length of 

the drain hose, including fittings. The drain should be 

installed in such a manner that water does not collect 

 

in sags or other low points, as condensation will form.

CAUTION

 

Pouring hot water down the drain may cause the Drain 

 

Tube to collapse. Allow only luke warm or cold water to 

 

enter the Drain Tube.

 

Pouring coffee, tea, or other 

 

similar substances down the drain may cause the Drain 

 

Tube to become clogged.

ATTENTION

A

A. Drain Fitting

B. Drain Line

C. Drip Tray

B

C

Remote Pump Installation

1.  If necessary, install water booster (Lancer PN MC-163172) 

between water supply and the unit.

2.  Using tubing cutters, cut water line and install tee fitting, then 

route appropriate tubing from the remote pump location to 

the tee fitting at water line. 

A

B

C

D

A. Tee Fitting

B. Line to Plain Water Inlet

C. Line to Water Source

D. Line to Remote Pump

3.  Connect line from tee fitting at water line to the remote pump 

deck inlet regulator.

4.  Complete the carbonated water line connection between the 

remote pump deck and carbonated water inlet on the unit.

A

B

C

A. Oetiker Pliers

B. Line to Tee Fitting

C. Pump Inlet     

D. Pump Outlet

D

5.  Install a shut-off valve in the water line feeding the deck. If a 

separate water line is run for plain water, ensure that it also 

has a shut-off valve.

A

A. Oetiker Pliers           C. Pump Inlet

B. Line to Unit 

         D. Pump Outlet

B

C

D

Installing Remote Syrup Pumps

1.  Install BIB rack and remote pumps according to              

manufacturers’ instructions.

2.  Once pumps and BIB rack are installed, measure and cut 

tubing to length between the pump CO

2

 inlets, then connect 

tubing to all pumps.

A

B

C

A. Syrup Pump

B. CO

2

 Line

C. Fitting

D. Oetiker Pliers

D

3.  Using tubing cutters, cut any pump CO

2

 supply line and 

install tee fitting, then route appropriate tubing from the CO

2

 

supply to the tee fitting at syrup pumps. 

4.  Connect tubing from dispenser syrup inlet to the syrup pump 

outlet fitting. Repeat for each syrup line/pump. 

A

B

C

A. Syrup Pump Outlet

B. Syrup Pump

C. Fitting

Содержание TouchPoint

Страница 1: ...s including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by...

Страница 2: ...ter supply line must be at least a 3 8 inches 9 525 mm pipe with a minimum of 25 PSI 0 172 MPA line pressure but not exceeding a maximum of 50 PSI 0 345 MPA Water pressure exceeding 50 PSI 0 345 MPA m...

Страница 3: ...r 2 Remove agitator bar from the hub 3 Remove ice shroud by lifting the side opposite the auger and rotating out from beneath the auger 4 Locate drain spider and reinstall in the coldplate cavity wher...

Страница 4: ...y cord to a grounded electrical outlet of the proper voltage and amperage rating Installing an Icemaker if necessary When installing an icemaker on the dispenser use a bin thermostat to control the ic...

Страница 5: ...Source D Line to Remote Pump 3 Connect line from tee fitting at water line to the remote pump deck inlet regulator 4 Complete the carbonated water line connection between the remote pump deck and car...

Страница 6: ...achment nut ATTENTION A CO2 Regulator B 1 4 Nut Stem Seal C Line to CO2 Regulator Manifold D Oetiker Pliers A B C D A dedicated CO2 regulator is required to supply the CO2 inlet at the unit as well as...

Страница 7: ...devices on the same outlet WARNING TouchPoint will begin booting up as soon as power is connected Boot up may take several minutes Cup selection carousel will appear when complete NOTE 7 Test the moto...

Страница 8: ...n 4 Selecting the different tabs on the left side of the screen will reveal even more available brands Tap Back to return to Technicians Menu 5 Tap the desired syrup brand Selected brand will become d...

Страница 9: ...syrup lines to avoid contamination DO NOT use strong bleaches or detergents These can discolor and corrode various materials DO NOT use metal scrapers sharp objects steel wool scouring pads abrasives...

Страница 10: ...plash Plate Assembly by lifting it up and out from the dispenser face Refer to the Automatic Agitation Warning on the first page of this manual NOTE It is recommended to perform this procedure monthly...

Страница 11: ...syrup lines with BIB connectors into cleaning solution 8 Activate each valve for a minimum of sixty 60 seconds until lines are filled with cleaning solution then let stand for thirty 30 minutes 9 Flus...

Страница 12: ...PLUMBING DIAGRAM ELECTRONICS DIAGRAM Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Отзывы: