manualshive.com logo in svg
background image

5

Dispenser Installation

 

The installation, and relocation if necessary, must 

be carried out by qualified personnel with up-to-date 

knowledge and practical experience, in accordance with 

current regulations.

NOTE

1.  Remove the cup rest, drip tray, and top cover from the unit.
2.  Twist/Rotate the ADA panel, located on the unit’s splash 

plate, in a counterclockwise direction up to a 45° angle.

7.  Connect tubing to water source then flush water lines to 

check for leaks.

8.  If necessary, install water booster (Lancer PN MC-163172) 

between water supply and the unit.

9.  Using tubing cutters, cut plain water line and install U-fitting 

then route appropriate tubing from the U-fitting to the  

carbonated water inlet at the unit.

A

B

A. Oetiker Pliers

B. Tubing

C. Syrup/Water Inlet

C

 

If a separate water line is run for plain water, ensure 

that it also has a shut-off valve.

NOTE

4.  Disconnect ADA harness and remove from the unit. Repeat 

Steps 2-4 for second ADA panel.

5.  Remove the unit’s splash plate and merchandiser.
6.  Route appropriate tubing from the water source to the plain 

water inlet at the front of the unit and connect tubing to inlet 

using the oetiker pliers and fittings,(see Plumbing Diagrams 

on the front of the unit or on page 12 for reference).

B

A

A. ADA Panel

B. Splash Plate

10.  Cut carbonated water line and install remote pump deck per 

manufacturer’s specifications.

A

B

C

A. Line to Water Source

B. U-Fitting

C. Carb Water Line

D. Plain Water Line

D

6.  Guide the edges of the merchandiser up, to the outside of 

the side brackets of the unit.

7.  Hook the top of the merchandiser to the manual fill ice chute. 

It is recommended to remove the front ice bin lid before 

installation.

8.  Verify that the connection tabs are locked in the openings on 

the sides of the merchandiser.

 

Merchandiser needs to be installed over the valve

 

plates for proper installation.

NOTE

CORRECT

INCORRECT

3.  Carefully pull ADA panel and electric wire harness from the 

unit’s splash plate, until the harness connector is visible.

A

A. Remote Pump Deck

B. Pump Inlet

C. Pump Outlet           

D. Line to Unit

B

C

D

11.  Complete the carbonated water line connection between the 

remote pump deck and carbonated water inlet at unit.

12.  Install a shut-off valve in the water line feeding the deck.

Содержание Sensation 44

Страница 1: ...cess or for your convenience scan this QR code with a mobile device app required for immediate access to other Technical Documents and alternative translations if available pertaining to this unit Con...

Страница 2: ...acity 312 lbs 142 kg CARBON DIOXIDE CO2 SUPPLY Min Pressure 70 psi 0 483 MPa Max Pressure 80 psi 0 552 MPa FITTINGS Carbonator Inlet 3 8 inch barb Plain Water Inlet 3 8 inch barb Brand Syrup Inlets 3...

Страница 3: ...weight of the dispenser ice and possibly an icemaker being installed after counter cut out is made Total weight with icemaker for this unit could exceed 800 pounds 363 6kg The dispenser should only b...

Страница 4: ...r use a bin thermostat to control the ice level see below This will prevent damage to the dispensing mechanism The bracket for mounting a thermostat is located in the ice bin During the automatic agit...

Страница 5: ...ubing from the water source to the plain water inlet at the front of the unit and connect tubing to inlet using the oetiker pliers and fittings see Plumbing Diagrams on the front of the unit or on pag...

Страница 6: ...nts as condensation will form CAUTION Pouring hot water down the drain may cause the Drain Tube to collapse Allow only luke warm or cold water to enter the Drain Tube Pouring coffee tea or other simil...

Страница 7: ...just both of the low pressure regulators on the regulator manifold to 75 psi 0 517 MPa then tighten locknut with wrench 11 Activate each valve until gas out 12 Plug in the remote carbonator pump deck...

Страница 8: ...quired to remove the merchandiser to gain access to valves NOTE 8 Using a Lancer ratio cup activate the valve and capture a sample Verify that the syrup level is even with the water level Use a screwd...

Страница 9: ...mum of five gallons of cleaning solution Do not use abrasive cleaners or solvents because they can cause permanent damage to the unit Ensure rinsing is thorough using clean potable water at a temperat...

Страница 10: ...on page 9 thoroughly wipe down the flavor injector nozzle and bracket then let air dry DO NOT rinse with water after sanitizing 6 Repeat Steps 2 5 for second flavor injector nozzle 7 Connect power 8...

Страница 11: ...om Ice Chute link by pushing pin through shaft until link is free Pin shown in out position A B C A Agitator Clip Pin B Hub C Agitator Bar 22 Remove the Agitator bar and Hub from the Ice Bin 23 Remove...

Страница 12: ...warm water and flush out syrup remaining in the lines 4 Prepare Cleaning Solution described on previous page 9 5 Place syrup lines with BIB connectors into cleaning solution 6 Activate each valve unt...

Страница 13: ...13 PLUMBING DIAGRAM Sensation 44 Unit Plumbing Diagram Sensation 44 Flavor Shot Box Plumbing Diagram...

Страница 14: ...14 WIRING DIAGRAMS Wiring Diagram 115 Volt...

Страница 15: ...15 Wiring Diagram 220 240 Volt...

Страница 16: ...6 7 6 2 2 3 8 3 4 7 4 5 SW1 SWITCH 1 NOT USED FOR MODEL 4900 ON 5 4 SWITCH AGITATOR ON TIME 5 6 OFF OFF 11 SECONDS OFF ON 9 SECONDS ON OFF 7 SECONDS ON ON 5 SECONDS SWITCH AUGER RUN TIME 7 8 OFF OFF 6...

Отзывы: