• WARNING:
Carbon Dioxide (CO2) is a colorless, noncombustible gas with a light pungent odor. High percentages of CO
2
may
displace oxygen in the blood.
• WARNING:
Prolonged exposure to CO
2
can be harmful. Personnel exposed to high concentrations of CO
2
gas will experience
tremors which are followed by a loss of consciousness and suffocation.
• WARNING:
If a CO
2
gas leak is suspected, immediately ventilate the contaminated area before attempting to repair the leak.
• WARNING:
Strict attention must be observed in the prevention of CO
2
gas leaks in the entire CO
2
and soft drink system.
5
Carbon Dioxide (CO
2
)
Provide an adequate potable water supply. Water pipe connections and fixtures directly connected to a potable water supply must
be sized, installed, and maintained according to federal, state, and local laws. The water supply line must be at least a 3/8 inches
(9.525 mm) pipe with a minimum of 75 psi (0.516 MPa) line pressure, but not exceeding a maximum of 125 psi (0.862 MPa).
Water pressure exceeding 125 psi (0.862 MPa) must be reduced to 125 psi (0.862 MPa) with the provided pressure regulator. Use
a filter in the water line to avoid equipment damage and beverage off-taste. Check the water filter periodically, as required by local
conditions. The water supply must be protected by means of an air gap, a backflow prevention device or another approved method
to comply with NSF standards. A leaking inlet water check valve will allow carbonated water to flow back through the pump when it
is shut off and contaminate the water supply. Ensure the backflow prevention device complies with ASSE and local standards. It is
the responsibility of the installer to ensure compliance.
!
Water Notice
SPECIFICATIONS & FEATURES
DIMENSIONS
Width
: 44.0 inches (1118 mm)
Depth
: 31.1 inches (791 mm)
Height
: 39.4 inches (1000 mm)
WEIGHT
Shipping
: 585 lbs (265 kg)
Operating (w/ Ice)
: 745 lbs (338 kg)
Ice Capacity
: 312 lbs (142 kg)
CARBON DIOXIDE (CO
2
) SUPPLY
Min Pressure
: 70 psi (0.483 MPa)
Max Pressure
: 80 psi (0.552 MPa)
FITTINGS
Carbonator Inlet
: 3/8 inch barb
Plain Water Inlet
: 3/8 inch barb
Brand Syrup Inlets
: 3/8 inch barb
CO
2
Inlet
: 3/8 inch barb
ELECTRICAL
115 VAC / 60 Hz / 6.0 Amps
220-240 VAC / 50-60 Hz / 3.0 Amps
PLAIN WATER SUPPLY
Min Flowing Pressure
: 75 psi (0.516 MPa)
CARBONATED WATER SUPPLY
Min Flowing Pressure
: 25 psi (0.172 MPa)
Max Static Pressure
: 50 psi (0.345 MPa)
This unit emits a sound pressure level below 70 dB
Check the dispenser name plate label, located behind the splash plate, for the correct electrical requirements of unit.
Do not plug
into a wall electrical outlet unless the current shown on the serial number plate agrees with local current available. Follow all local
electrical codes when making connections. Each dispenser must have a separate electrical circuit. Do not use extension cords with
this unit. Do not ‘gang’ together with other electrical devices on the same outlet. The keyswitch does not disable the line voltage to
the transformer primary. Always disconnect electrical power to the unit to prevent personal injury before attempting any internal
maintenance. The resettable breaker switch should not be used as a substitute for unplugging the dispenser from the power source
to service the unit. Only qualified personnel should service internal components of electrical control housing. Make sure that all
water lines are tight and units are dry before making any electrical connections!
F
Electrical Warning
Adjusting Three-Way Adjustable Back Blocks
1. This feature allows for flexibility between carbonated or plain
water drinks on the valves of your choice.
2. To set the adjustable back blocks, turn the shut-off stem to
the desired location, refer to the image on the right:
There is 100% flexibility on valves 4 - 9. Valves 1 - 3 and
10 - 12 are only plumbed for carbonated water drinks
and are non-adjustable. See Plumbing Diagram on page
12 for reference.
NOTE
A
B
C
A. Plain Water ON D. Water Closed
B. Carb Water ON E. Syrup Closed
C. Syrup ON
D
E