manualshive.com logo in svg
background image

11

 

DO NOT

 disconnect flavor lines from nozzle, when 

 

removing from bracket.

NOTE

 

Always remove the ice chute lever before removing the 

 

splash plate.

NOTE

4.  Remove or melt out any remaining ice from the ice bin.
5.  Disconnect the two (2) lower, horizontal LED light bars and 

remove from unit.

6.  Disconnect vertical LED light bar, next to flavor injector  

nozzle, from the junction box and remove from unit. 

7.  Repeat previous step for second light bar on opposite side of 

the unit.

8.  Rotate the flavor injector nozzle 90° to disconnect from 

bracket.

11.  Disconnect the Auger Motor wire harness from junction box.
12.  Remove the four (4) screws from the bracket holding the 

Auger Motor, flavor injector bracket, and LED light bracket.

13.  Slide the Motor and Mounting Plate Assembly off of the 

Auger Shaft.

C

A

B

A. Auger Motor

B. Auger Shaft

C. Solenoid

A

B

C

A. Auger Motor Shaft

B. “C” Clip

C. Ice Chute

9.  Use a screwdriver to remove the Auger Motor shaft cover.
10.  Remove the “C” clip from the Auger Motor Shaft.

14.  Remove the Auger Motor Shaft Key and set aside.
15.  Remove the second clip from the Auger Shaft.
16.  Disconnect the Ice Chute wire harness from the junction box.

C

A

B

A. Solenoid

B. Solenoid Pin

C. Ice Chute Link

17.  Disconnect the solenoid from Ice Chute link by pushing pin 

through shaft until link is free. (Pin shown in out position)

A

B

C

A. Agitator Clip/Pin

B. Hub

C. Agitator Bar

22.  Remove the Agitator bar and Hub from the Ice Bin.
23.  Remove the plastic Ice Shroud by”pinching” in the center 

and rotating out.

24.  Using the Cleaning Solution (page 9) and a clean cloth or 

soft brush, clean the Ice Chute Assembly, Ice Shroud, Auger, 

all sides of the Ice Bin, and surface of the aluminum casting.

25.  Using the Cleaning Solution and the sponge brush provided, 

clean all interior surfaces of the ice chute and the ice chute 

feed through.

26.  Using hot water, thoroughly rinse away the cleaning solution.
27.  Wearing sanitary gloves, use a clean cloth or towel and the 

Sanitizing Solution (page 9) to wash all surfaces of remov-

able parts, sides of the Ice Bin, and surface of the aluminum 

casting.

28.  Using the Sanitizing Solution and the sponge brush          

provided, clean all interior surfaces of the ice chute and the 

ice chute feed through.

29.  Wearing sanitary gloves, reassemble all removable parts. 

Ensure agitator clip is locked.

30.  Fill unit with ice and replace Top Cover.
31.  Reconnect Dispenser to power source.

18.  Remove the Ice Chute Assembly by removing four (4) 

screws that secure to unit and set aside.

19.  Remove Auger by pulling straight out from unit and set aside.
20.  Repeat Steps 5 - 14 for second Auger Motor Assembly.
21.  Remove Agitator Clip and Pin from Agitator bar in Ice Bin.

Содержание Sensation 44

Страница 1: ...cess or for your convenience scan this QR code with a mobile device app required for immediate access to other Technical Documents and alternative translations if available pertaining to this unit Con...

Страница 2: ...acity 312 lbs 142 kg CARBON DIOXIDE CO2 SUPPLY Min Pressure 70 psi 0 483 MPa Max Pressure 80 psi 0 552 MPa FITTINGS Carbonator Inlet 3 8 inch barb Plain Water Inlet 3 8 inch barb Brand Syrup Inlets 3...

Страница 3: ...weight of the dispenser ice and possibly an icemaker being installed after counter cut out is made Total weight with icemaker for this unit could exceed 800 pounds 363 6kg The dispenser should only b...

Страница 4: ...r use a bin thermostat to control the ice level see below This will prevent damage to the dispensing mechanism The bracket for mounting a thermostat is located in the ice bin During the automatic agit...

Страница 5: ...ubing from the water source to the plain water inlet at the front of the unit and connect tubing to inlet using the oetiker pliers and fittings see Plumbing Diagrams on the front of the unit or on pag...

Страница 6: ...nts as condensation will form CAUTION Pouring hot water down the drain may cause the Drain Tube to collapse Allow only luke warm or cold water to enter the Drain Tube Pouring coffee tea or other simil...

Страница 7: ...just both of the low pressure regulators on the regulator manifold to 75 psi 0 517 MPa then tighten locknut with wrench 11 Activate each valve until gas out 12 Plug in the remote carbonator pump deck...

Страница 8: ...quired to remove the merchandiser to gain access to valves NOTE 8 Using a Lancer ratio cup activate the valve and capture a sample Verify that the syrup level is even with the water level Use a screwd...

Страница 9: ...mum of five gallons of cleaning solution Do not use abrasive cleaners or solvents because they can cause permanent damage to the unit Ensure rinsing is thorough using clean potable water at a temperat...

Страница 10: ...on page 9 thoroughly wipe down the flavor injector nozzle and bracket then let air dry DO NOT rinse with water after sanitizing 6 Repeat Steps 2 5 for second flavor injector nozzle 7 Connect power 8...

Страница 11: ...om Ice Chute link by pushing pin through shaft until link is free Pin shown in out position A B C A Agitator Clip Pin B Hub C Agitator Bar 22 Remove the Agitator bar and Hub from the Ice Bin 23 Remove...

Страница 12: ...warm water and flush out syrup remaining in the lines 4 Prepare Cleaning Solution described on previous page 9 5 Place syrup lines with BIB connectors into cleaning solution 6 Activate each valve unt...

Страница 13: ...13 PLUMBING DIAGRAM Sensation 44 Unit Plumbing Diagram Sensation 44 Flavor Shot Box Plumbing Diagram...

Страница 14: ...14 WIRING DIAGRAMS Wiring Diagram 115 Volt...

Страница 15: ...15 Wiring Diagram 220 240 Volt...

Страница 16: ...6 7 6 2 2 3 8 3 4 7 4 5 SW1 SWITCH 1 NOT USED FOR MODEL 4900 ON 5 4 SWITCH AGITATOR ON TIME 5 6 OFF OFF 11 SECONDS OFF ON 9 SECONDS ON OFF 7 SECONDS ON ON 5 SECONDS SWITCH AUGER RUN TIME 7 8 OFF OFF 6...

Отзывы: