Dispenser Setup

1.  Turn on water source.
2.  Open the pressure relief valve located on the front of the 

unit, by flipping up on the valve cap lever. Hold open until 

water flows from the relief valve then close (flip down) the 

relief valve.

 

The dispenser must be properly electrically grounded 

to avoid serious injury or fatal electrical shock. The 

power cord has a three-prong grounded plug. If a 

three-hole grounded electrical outlet is not available, 

use an approved method to ground the unit. Follow all 

local electrical codes when making connections. Each 

dispenser must have a separate electrical circuit. Do 

not use extension cords. Do not connect multiple 

 

electrical devices on the same outlet.

WARNING

5.  Connect tubing routed from the tee at the syrup pumps to 

the second outlet of the low pressure CO

2

 regulator manifold. 

A

B

C

D

A. Line to Dispenser

B. Line to Syrup Pumps

C. Line to CO

2

 Regulator

D. CO

2

 Regulator Manifold

6.  Using a wrench, loosen lock nut on the regulator adjustment 

screw of the high pressure CO

2

 regulator connected to the 

source, then using a screwdriver back out lock nut screw all 

the way.

 

DO NOT TURN ON CO

2

 SUPPLY AT THIS TIME

WARNING

7.  Repeat Step 6 for both low pressure CO

2

 regulators on the 

regulator manifold routed to the unit and the syrup pumps.  

A. Regulator Adjustment Screw

B. Adjust to 110 psi (0.758 MPa)

C. Wrench

A

B

C

10.  Adjust both of the low pressure regulators on the regulator 

manifold to 75 psi (0.517 MPa) then tighten locknut with 

wrench.  

11.  Activate each valve until gas-out.
12.  Plug in the remote carbonator pump deck, if not already 

done so, and turn the switch to the ON position.

13.  Activate each valve until the carbonator pump comes on.  

Release the button, allow carbonator to fill and stop.  

Repeat this process until a steady flow of carbonated water 

is achieved.

14.  Activate each valve to purge air from the syrup lines. 

The pump deck has a 3 minute timeout feature. If the 

timeout occurs, turn the deck OFF then ON by flipping 

the switch on the control box.

NOTE

To check for CO

2

 leaks, close the valve on the CO

2

  

cylinder and observe if the pressure to the system 

drops with the  cylinder valve closed for five minutes. 

 

Open the cylinder valve after check.

NOTE

6.  Test the motor operation by pushing both ice chute levers 

until agitator motor begins to turn. 

7.  Activate each valve to ensure a good flow of water is 

achieved. 

8.  Ensure pump deck is turned OFF before turning on CO

2

9.  Turn on CO

2

 at the source then, using a screwdriver, adjust 

the high pressure regulator at the source to 110 psi (0.758 

MPa) then tighten locknut with wrench. 

A. CO

2

 Regulator

B. Screwdriver

C. Regulator Adjustment Screw

A

B

C

A

B

A. Pressure Relief Valve

B. CO

2

 Inlet

3.  Verify all Bag-In-Box contains syrup and check all  

connections for leaks.

4.  Place enough ice in the ice bin to fill approximately 1/2 of the 

bin before plugging in the unit.

5.  Connect unit power cord to grounded electrical outlet. 

Содержание Sensation 44

Страница 1: ...cess or for your convenience scan this QR code with a mobile device app required for immediate access to other Technical Documents and alternative translations if available pertaining to this unit Con...

Страница 2: ...acity 312 lbs 142 kg CARBON DIOXIDE CO2 SUPPLY Min Pressure 70 psi 0 483 MPa Max Pressure 80 psi 0 552 MPa FITTINGS Carbonator Inlet 3 8 inch barb Plain Water Inlet 3 8 inch barb Brand Syrup Inlets 3...

Страница 3: ...weight of the dispenser ice and possibly an icemaker being installed after counter cut out is made Total weight with icemaker for this unit could exceed 800 pounds 363 6kg The dispenser should only b...

Страница 4: ...r use a bin thermostat to control the ice level see below This will prevent damage to the dispensing mechanism The bracket for mounting a thermostat is located in the ice bin During the automatic agit...

Страница 5: ...ubing from the water source to the plain water inlet at the front of the unit and connect tubing to inlet using the oetiker pliers and fittings see Plumbing Diagrams on the front of the unit or on pag...

Страница 6: ...nts as condensation will form CAUTION Pouring hot water down the drain may cause the Drain Tube to collapse Allow only luke warm or cold water to enter the Drain Tube Pouring coffee tea or other simil...

Страница 7: ...just both of the low pressure regulators on the regulator manifold to 75 psi 0 517 MPa then tighten locknut with wrench 11 Activate each valve until gas out 12 Plug in the remote carbonator pump deck...

Страница 8: ...quired to remove the merchandiser to gain access to valves NOTE 8 Using a Lancer ratio cup activate the valve and capture a sample Verify that the syrup level is even with the water level Use a screwd...

Страница 9: ...mum of five gallons of cleaning solution Do not use abrasive cleaners or solvents because they can cause permanent damage to the unit Ensure rinsing is thorough using clean potable water at a temperat...

Страница 10: ...on page 9 thoroughly wipe down the flavor injector nozzle and bracket then let air dry DO NOT rinse with water after sanitizing 6 Repeat Steps 2 5 for second flavor injector nozzle 7 Connect power 8...

Страница 11: ...om Ice Chute link by pushing pin through shaft until link is free Pin shown in out position A B C A Agitator Clip Pin B Hub C Agitator Bar 22 Remove the Agitator bar and Hub from the Ice Bin 23 Remove...

Страница 12: ...warm water and flush out syrup remaining in the lines 4 Prepare Cleaning Solution described on previous page 9 5 Place syrup lines with BIB connectors into cleaning solution 6 Activate each valve unt...

Страница 13: ...13 PLUMBING DIAGRAM Sensation 44 Unit Plumbing Diagram Sensation 44 Flavor Shot Box Plumbing Diagram...

Страница 14: ...14 WIRING DIAGRAMS Wiring Diagram 115 Volt...

Страница 15: ...15 Wiring Diagram 220 240 Volt...

Страница 16: ...6 7 6 2 2 3 8 3 4 7 4 5 SW1 SWITCH 1 NOT USED FOR MODEL 4900 ON 5 4 SWITCH AGITATOR ON TIME 5 6 OFF OFF 11 SECONDS OFF ON 9 SECONDS ON OFF 7 SECONDS ON ON 5 SECONDS SWITCH AUGER RUN TIME 7 8 OFF OFF 6...

Отзывы: