24
P.N. 28-0558/04
L.
Hold the Lancer brix cup under the syrup separator and activate valve. Check brix.
M. To obtain the proper brix, use screwdriver to adjust syrup flow control.
N. Once proper ratio is obtained, repeat to verify.
O. Repeat for each valve.
P.
Remove syrup separator.
Q. Install nozzle.
R. Once all the valves have been brixed, restore switches panel and light panel to their original
positions.
3.6 CARBONATOR PUMP MODIFICATIONS
The electric, positive displacement rotary vane pump with 170 PSI bypass should only be serviced
by trained personnel. To achieve optimum carbonation, use filtered water with the pump.
A. Servicing
1.
Turn off power to the dispenser.
2.
Remove drip tray and splash plate.
3.
Turn off water.
4.
Turn the CO
2
off, activate the relief valve.
5.
Once the pressure has been released, untighten the inlet/outlet nuts on the pump.
6.
Unscrew the mounting bracket.
7.
Part should easily slide out for replacement or maintenance.
Содержание Flavor Select 30
Страница 11: ...11 P N 28 0558 04 1 4 INSTALLATION OVERVIEW 1...
Страница 12: ...12 P N 28 0558 04 1 5 INSTALLATION OVERVIEW 2...
Страница 25: ...25 P N 28 0558 04 NOTES...